American Standard AUY060R9V3W Service Facts

Download Service facts of American Standard ADY060R9V3W Furnace for Free or View it Online on All-Guides.com. This version of American Standard ADY060R9V3W Manual compatible with such list of devices, as: ADY060R9V3W, ADY100R9V4W, ADY120R9V5W, AUY060R9V3W, TDY060R9V3W

American Standard ADY060R9V3W Service facts - Page 1
1
American Standard ADY060R9V3W Service facts - Page 2
2
American Standard ADY060R9V3W Service facts - Page 3
3
American Standard ADY060R9V3W Service facts - Page 4
4
American Standard ADY060R9V3W Service facts - Page 5
5
American Standard ADY060R9V3W Service facts - Page 6
6
American Standard ADY060R9V3W Service facts - Page 7
7
American Standard ADY060R9V3W Service facts - Page 8
8
American Standard ADY060R9V3W Service facts - Page 9
9
American Standard ADY060R9V3W Service facts - Page 10
10
American Standard ADY060R9V3W Service facts - Page 11
11
American Standard ADY060R9V3W Service facts - Page 12
12
American Standard ADY060R9V3W Service facts - Page 13
13
American Standard ADY060R9V3W Service facts - Page 14
14
American Standard ADY060R9V3W Service facts - Page 15
15
American Standard ADY060R9V3W Service facts - Page 16
16
American Standard ADY060R9V3W Service facts - Page 17
17
American Standard ADY060R9V3W Service facts - Page 18
18
American Standard ADY060R9V3W Service facts - Page 19
19
American Standard ADY060R9V3W Service facts - Page 20
20
Service Facts
© 2005 American Standard Inc. All Rights Reserved
NOTICE: Since the manufacturer has a policy of continuous product and product data improvement,
it reserves the right to change design and specifications without notice.
B - FURNACES
PRODUCT SPECIFICATIONS
1
MODEL
TYPE
RATINGS 2
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
3
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT — Size (in.)
HEAT EXCHANGER
Type -Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
*UY080R9V3W
Upflow / Horizontal
52,000
48,000
80,000
73,000
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
4
115/1/60
11.1
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
168 / 156
Gas Furnace – Var. Speed Blower –
Var. Speed Inducer – Two Stage Heat –
Direct Vent
Models: * - First letter may be “A” or “T”
*UY060R9V3W *DY060R9V3W
*UY080R9V3W *DY080R9V3W
*UY100R9V4W *DY100R9V4W
*UY120R9V5W *DY120R9V5W
Page B-651-438
W.M. 1/05R
IMPORTANT — This document contains a wiring diagram and service information. This is customer property and is to
remain with this unit. Please return to service information pack upon completion of work.
DISCONNECT POWER BEFORE SERVICING
WARNING
*UY060R9V3W
Upflow / Horizontal
39,000
37,000
60,000
56,000
35 - 65
DIRECT
10 x 8
1
Variable
See Fan Performance Table
1/2
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 17x25 - 1 in.
2 Round
Aluminized Steel - Type I
20
3 — 45
3 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
3
115/1/60
11.1
15
1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
158 / 146
*UY100R9V4W
Upflow / Horizontal
65,000
60,000
100,000
93,000
35 - 65
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 20x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
5
115/1/60
13.5
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
197 / 185
*UY120R9V5W
Upflow / Horizontal
78,000
72,000
120,000
112,000
40 - 70
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1
Variable
115/1/60
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Yes
High Velocity
1 - 24x25 - 1 in.
3 Round
Aluminized Steel - Type I
20
6 — 45
6 — 56
Redundant - Two Stage
Hot Surface Igniter
Multiport Inshot
6
115/1/60
15.2
20
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
206 / 193
1 Central Furnace heating designs are certified by AGA and CSA.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
X341119P12