Johnson Controls TEC2004-4 Installation Instructions Manual

Download Installation instructions manual of Johnson Controls TEC2004-4 Thermostat for Free or View it Online on All-Guides.com.

Johnson Controls TEC2004-4 Installation instructions manual - Page 1
1
Johnson Controls TEC2004-4 Installation instructions manual - Page 2
2
Johnson Controls TEC2004-4 Installation instructions manual - Page 3
3
Johnson Controls TEC2004-4 Installation instructions manual - Page 4
4
Johnson Controls TEC2004-4 Installation instructions manual - Page 5
5
Johnson Controls TEC2004-4 Installation instructions manual - Page 6
6
Johnson Controls TEC2004-4 Installation instructions manual - Page 7
7
Johnson Controls TEC2004-4 Installation instructions manual - Page 8
8
Johnson Controls TEC2004-4 Installation instructions manual - Page 9
9
Johnson Controls TEC2004-4 Installation instructions manual - Page 10
10
Johnson Controls TEC2004-4 Installation instructions manual - Page 11
11
Johnson Controls TEC2004-4 Installation instructions manual - Page 12
12
Johnson Controls TEC2004-4 Installation instructions manual - Page 13
13
Johnson Controls TEC2004-4 Installation instructions manual - Page 14
14
Johnson Controls TEC2004-4 Installation instructions manual - Page 15
15
Johnson Controls TEC2004-4 Installation instructions manual - Page 16
16
TEC2004-4 and TEC2004-4+PIR Multi-Stage Economizer Wireless Thermostat
Controller Installation Instructions
1
Applications
The TEC Series Wireless Thermostat Controller
System provides wireless networked control of
Heating, Ventilating, and Air Conditioning (HVAC)
equipment on a Building Automation System (BAS)
that enables remote monitoring and programming. This
TEC Series System integrates into a supervisory
controller that uses BACnet® Internet Protocol (IP) or
BACnet Master-Slave/Token-Passing (MS/TP)
communications.
TEC20 Coordinators allow the supervisory controller to
communicate with multiple TEC Wireless Thermostat
Controllers. TEC200x-4 Series Wireless Thermostat
Controllers provide networked control of a variety of
staged equipment. TEC2004-4 and TEC2004-4+PIR
Multi-Stage Economizer Wireless Thermostat
Controllers control economizer operation for single-
and multi-stage unitary rooftop equipment.
The TEC2004-4+PIR Thermostat Controller provides
advanced active occupancy logic that automatically
switches occupancy from Occupied to Unoccupied as
required by the presence of local activity. See the
Occupancy Sensor Operation – TEC2004-4+PIR
Thermostat Controller section for more information.
The wireless mesh network uses ZigBee™ technology
to enable remote monitoring and programming and to
enhance reliability by providing redundant transmission
paths through other TEC Wireless Thermostat
Controllers, creating a resilient, self-healing mesh
network.
North American Emissions Compliance
United States
IMPORTANT: The TEC2004-4 and
TEC2004-4+PIR Wireless Thermostat Controllers
are intended to provide an input to equipment under
normal operating conditions. Where failure or
malfunction of the thermostat controller could lead to
personal injury or property damage to the controlled
equipment or other property, additional precautions
must be designed into the control system.
Incorporate and maintain other devices, such as
supervisory or alarm systems or safety or limit
controls, intended to warn of or protect against
failure or malfunction of the thermostat controller.
This equipment has been tested and found to
comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when this equipment is
operated in a commercial environment. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is
likely to cause harmful interference, in which case
the user will be required to correct the interference
at his/her own expense.
RF Transmitters: Compliance Statement
(Part 15.19)
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference,
and
2. This device must accept any interference
received, including interference that may cause
undesired operation.
Warning (Part 15.21)
Changes or modifications not expressly approved by
the party responsible for compliance could void the
user’s authority to operate the equipment.
TEC2004-4 and TEC2004-4+PIR Multi-Stage Economizer
Wireless Thermostat Controller
Installation Instructions
TEC2004-4 and TEC2004-4+PIR
Part No. 24-9890-1168, Rev. B
Issued July 13, 2010
Supersedes May 17, 2010