Winterhalter UC-S Operating Instructions Manual

Download Operating instructions manual of Winterhalter UC series Dishwasher, Industrial Equipment for Free or View it Online on All-Guides.com. This version of Winterhalter UC series Manual compatible with such list of devices, as: UC series, UC-L, UC-M, UC-S, UC-XL

Winterhalter UC series Operating instructions manual - Page 1
1
Winterhalter UC series Operating instructions manual - Page 2
2
Winterhalter UC series Operating instructions manual - Page 3
3
Winterhalter UC series Operating instructions manual - Page 4
4
Winterhalter UC series Operating instructions manual - Page 5
5
Winterhalter UC series Operating instructions manual - Page 6
6
Winterhalter UC series Operating instructions manual - Page 7
7
Winterhalter UC series Operating instructions manual - Page 8
8
Winterhalter UC series Operating instructions manual - Page 9
9
Winterhalter UC series Operating instructions manual - Page 10
10
Winterhalter UC series Operating instructions manual - Page 11
11
Winterhalter UC series Operating instructions manual - Page 12
12
Winterhalter UC series Operating instructions manual - Page 13
13
Winterhalter UC series Operating instructions manual - Page 14
14
Winterhalter UC series Operating instructions manual - Page 15
15
Winterhalter UC series Operating instructions manual - Page 16
16
Winterhalter UC series Operating instructions manual - Page 17
17
Winterhalter UC series Operating instructions manual - Page 18
18
Winterhalter UC series Operating instructions manual - Page 19
19
Winterhalter UC series Operating instructions manual - Page 20
20
Winterhalter UC series Operating instructions manual - Page 21
21
Winterhalter UC series Operating instructions manual - Page 22
22
Winterhalter UC series Operating instructions manual - Page 23
23
Winterhalter UC series Operating instructions manual - Page 24
24
Winterhalter UC series Operating instructions manual - Page 25
25
Winterhalter UC series Operating instructions manual - Page 26
26
Winterhalter UC series Operating instructions manual - Page 27
27
Winterhalter UC series Operating instructions manual - Page 28
28
Winterhalter UC series Operating instructions manual - Page 29
29
Winterhalter UC series Operating instructions manual - Page 30
30
Winterhalter UC series Operating instructions manual - Page 31
31
Winterhalter UC series Operating instructions manual - Page 32
32
Winterhalter UC series Operating instructions manual - Page 33
33
Winterhalter UC series Operating instructions manual - Page 34
34
Winterhalter UC series Operating instructions manual - Page 35
35
Winterhalter UC series Operating instructions manual - Page 36
36
Winterhalter UC series Operating instructions manual - Page 37
37
Winterhalter UC series Operating instructions manual - Page 38
38
Winterhalter UC series Operating instructions manual - Page 39
39
Winterhalter UC series Operating instructions manual - Page 40
40
Winterhalter UC series Operating instructions manual - Page 41
41
Winterhalter UC series Operating instructions manual - Page 42
42
Winterhalter UC series Operating instructions manual - Page 43
43
Winterhalter UC series Operating instructions manual - Page 44
44
Winterhalter UC series Operating instructions manual - Page 45
45
Winterhalter UC series Operating instructions manual - Page 46
46
Winterhalter UC series Operating instructions manual - Page 47
47
Winterhalter UC series Operating instructions manual - Page 48
48
Electrical connection
43
20.1 Mains connection cable
Gefahr
DANGER! Risk of fatal injury due to live components!
The connecting cable may only be changed or replaced by the manufacturer, its
customer service representative or a similarly qualified person. Use an H07 RN-F type
cable or equivalent.
The machines of the UC series are delivered with or without mains connection cable.
Requirements to the mains connection cable
¾ Use a cable of the type H07 RN-F or equivalent
¾ Section and number of wires appropriate for voltage, fusing and overall connection value
Connection of the mains connection cable in the machine
Exemplary images for a UC-L
Remove the front cladding
UC-S: additionally remove the
right side cladding
Remove the bulkhead (1) towards the electric installation compartment
Insert the mains connection cable
through the backside of the ma-
chine and guide it to the connec-
tion terminals at the front
Strain relief
UC-M, UC-L, UC-XL
Tighten the screwed cable con-
nection in the electric installation
compartment
UC-S
Tighten the screwed cable con-
nection at the backside of the
machine
Connect the mains connection
cable to the terminals PE to N
according to the connection
scheme.
Observe the connection scheme
fixed at the bulkhead of the elec-
tric installation compartment.
Boiler heating element
The boiler heating element is already connected. However, jumpers must be plugged in, in order not to ex-
ceed the fusing values of the mains network.
¾ Please observe the connection scheme fixed at the bulkhead of the electric installation compartment.
20.2 Bonding connection
Integrate the machine and any plinths and table systems in the on-site equipotential bonding system. The
connection points are labelled accordingly.
There is a screw connection point marked with the earth symbol
at the back of the machine, to which the
earth lead must be connected.