HP Prime Graphing Calculator Quick Start Manual

Download Quick start manual of HP Prime Graphing Calculator Calculator for Free or View it Online on All-Guides.com.

HP Prime Graphing Calculator Quick start manual - Page 1
1
HP Prime Graphing Calculator Quick start manual - Page 2
2
HP Prime Graphing Calculator Quick start manual - Page 3
3
HP Prime Graphing Calculator Quick start manual - Page 4
4
HP Prime Graphing Calculator Quick start manual - Page 5
5
HP Prime Graphing Calculator Quick start manual - Page 6
6
HP Prime Graphing Calculator Quick start manual - Page 7
7
HP Prime Graphing Calculator Quick start manual - Page 8
8
HP Prime Graphing Calculator Quick start manual - Page 9
9
HP Prime Graphing Calculator Quick start manual - Page 10
10
HP Prime Graphing Calculator Quick start manual - Page 11
11
HP Prime Graphing Calculator Quick start manual - Page 12
12
HP Prime Graphing Calculator Quick start manual - Page 13
13
HP Prime Graphing Calculator Quick start manual - Page 14
14
HP Prime Graphing Calculator Quick start manual - Page 15
15
HP Prime Graphing Calculator Quick start manual - Page 16
16
HP Prime Graphing Calculator Quick start manual - Page 17
17
HP Prime Graphing Calculator Quick start manual - Page 18
18
HP Prime Graphing Calculator Quick start manual - Page 19
19
HP Prime Graphing Calculator Quick start manual - Page 20
20
HP Prime Graphing Calculator Quick start manual - Page 21
21
HP Prime Graphing Calculator Quick start manual - Page 22
22
HP Prime Graphing Calculator Quick start manual - Page 23
23
HP Prime Graphing Calculator Quick start manual - Page 24
24
HP Prime Graphing Calculator Quick start manual - Page 25
25
HP Prime Graphing Calculator Quick start manual - Page 26
26
HP Prime Graphing Calculator Quick start manual - Page 27
27
HP Prime Graphing Calculator Quick start manual - Page 28
28
HP Prime Graphing Calculator Quick start manual - Page 29
29
HP Prime Graphing Calculator Quick start manual - Page 30
30
HP Prime Graphing Calculator Quick start manual - Page 31
31
HP Prime Graphing Calculator Quick start manual - Page 32
32
HP Prime Graphing Calculator Quick start manual - Page 33
33
HP Prime Graphing Calculator Quick start manual - Page 34
34
HP Prime Graphing Calculator Quick start manual - Page 35
35
HP Prime Graphing Calculator Quick start manual - Page 36
36
HP Prime Graphing Calculator Quick start manual - Page 37
37
HP Prime Graphing Calculator Quick start manual - Page 38
38
HP Prime Graphing Calculator Quick start manual - Page 39
39
HP Prime Graphing Calculator Quick start manual - Page 40
40
HP Prime Graphing Calculator Quick start manual - Page 41
41
HP Prime Graphing Calculator Quick start manual - Page 42
42
HP Prime Graphing Calculator Quick start manual - Page 43
43
HP Prime Graphing Calculator Quick start manual - Page 44
44
HP Prime Graphing Calculator Quick start manual - Page 45
45
HP Prime Graphing Calculator Quick start manual - Page 46
46
HP Prime Graphing Calculator Quick start manual - Page 47
47
HP Prime Graphing Calculator Quick start manual - Page 48
48
HP Prime Graphing Calculator Quick start manual - Page 49
49
HP Prime Graphing Calculator Quick start manual - Page 50
50
HP Prime Graphing Calculator Quick start manual - Page 51
51
HP Prime Graphing Calculator Quick start manual - Page 52
52
36 Quick Start Guide
—Specify a data column, or, when a Fitn field is selected, to enter or edit a fit equation. If you enter your own fit
equation, the corresponding Typen field automatically changes to User Defined.
—Displays a menu where you can select a type of fit: linear, logarithmic, exponential, and so on; visible only
when a Typen field is selected.
—Toggles between making an analysis active or inactive.
—Opens a list of available columns of data that you can select; visible only when an Sn field is selected.
•—Enters an X when tapped; visible only when a Fitn field is selected.
—Specifies whether a graph of the type chosen will be plotted when you display Plot view. If this is not selected,
only the data points are plotted.
—Displays the selection in textbook format in full-screen view; visible only when an Sn or Fitn field is selected.
—Evaluates the variables in whatever is selected; visible only when an Sn or Fitn field is selected.
When specifying dependent and independent columns in the Sn fields, you can enter column names (for example, C1) or
mathematical expressions in terms of column names (for example, 2*C1).
Plot view Press P to display the Plot view. This view displays the scatter plot for
each selected analysis. Tap to display (or hide) the full menu for this view. The
menu items are as follows:
: Displays the Zoom menu, with options to zoom in or out. You can also
press + to zoom in and : to zoom out on the trace. Use a 2-finger pinch
zoom gesture to perform a horizontal, vertical, or square zoom in or out.
—Toggles the tracing cursor off and on. With the tracing cursor on, you
can press R or L to move from data point to data point. The values of each point
are displayed at the bottom of the screen. If a fit equation is displayed, you can
press U or D to trace the equation instead. Press R or L to move along the
equation. Values of the dependent variable, as predicted by the fit equation, are displayed at the bottom of the screen.
—Takes the tracing cursor to the point you specify (or to the closest point).
—Shows (or hides) the graph of the fit equation.
—Displays the columns used to define the graph or, if the tracing cursor is
on a point on the graph of the fit equation, the definition of the fit equation. You
can also see the fit equation by returning to Symbolic view and looking at the
corresponding Fitn field.
Plot Setup view Press SP to display page 1 of the Statistics 2Var Plot Setup
view. This view is similar to page 1 of the Statistics 1Var Plot Setup view, except that
the H Width and H Rng fields have been replaced with fields that enable you too
choose different data-point marks for each scatter plot.
Page 2 of this view is identical to page 2 of the Function Plot Setup view (see “Function, Advanced Graphing, Parametric,
Polar, and Sequence apps” on page 22) except for the addition of a Connect field. If this field is selected, the data points are
connected by straight segments. Note that these segments do not constitute a fit.