Inst cti n heet
Evaporator rainTray Assembly Installation
Refrigerator Models: EF42BDCB, EF48BDCB, EF42BNDB,
EF48BNDB, IF42BDCB, IF48BDCB, IF42BNDB, IF48BNDB
Kit Part Numbers: W10199913 (42=inch models), W10199915 (48=inch models)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death
or electrical shock.
Kit Contains:
1 Clip 6 Sealer-Gum (Butyl)
1 Clamp 1 Evaporator DrainTray Assembly
1 Drain Tube 1 instruction Sheet
Standard product manufacturing warranty applies.
IMPORTANT: Evaporator Drain Tray Freeze Up issue in 2003
thru 2007 production - Creates internal water leak from ceiling
of freezer causing water and ice to accumulate on the ceiling,
door and seals of freezer. Can also cause a no cool situation, a
noise issue when ice forms blocking evaporator motor and blade,
or damper diffuser failure.
NOTE: All steps must be followed for a proper repair.
1. Remove top grille.
2. Turn off power. See Figure 1.
POWER
SWITCH
FIGURE1
3. Remove evaporator cover and components inorder to access
the evaporator drain tray.
4. Remove evaporator drain tray.
5. Clear any remaining ice off the evaporator and on the back
wall.
6. On the left side of the evaporator, remove and discard the
piece of foam. it will not be needed. See Figure 2.
NOTE: The foam piece might come off the evaporator and be
stuck on the old evaporator drain tray when removed.
FIGURE2
7. Locate and unplug evaporator defrost thermistor at the
connector. The defrost thermistor is mounted on the
evaporator. Follow wire and disconnect at the connector.
Leave the defrost thermistor permanently disconnected. See
Figure 3.
NOTE: This will initiate a 6 hour defrost cycle time, keeping the
evaporator clear from any ice build up.
IMPORTANT: Do not disconnect the Defrost Bi-Metal.
FIGURE3