SAA8012
Door contact alarm
User Manual
Keep this manual safe for future reference
18
Specifications
All devices
EMC
Tested to ETS 300 683
Radio Components tested to EN
300 220-1
Environmental conditions
-10°C to 40°C, relative humidity
70% non-condensing for all units
except the external siren. Siren: -20°C
to 50°C, relative humidity 95% non-
condensing
Radio operational range
30m in a typical domestic
installation, range can vary depending
on building construction, device
positions and RF environment
Housings ABS/polycarbonate
Siren
Siren output 104dBA sound pressure @
1m minimum
Radio 433.92MHz AM super heterodyne
receiver with jamming detection
Power supply 6V, 4 x D alkaline cells. 3
years typical service life
Passive infra red (PIR) detector
Alarm processing Microprocessor
controlled dual edge sequential pulse
count with pulse length discrimination
Radio 433.92MHz AM transmitter
Power supply 4.5V, 3 x AA alkaline cells.
3 years typical domestic service life, 1-
minute sleep timer
Movement detection range 15m, 11
Door/window contact
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 3V, 2 x AAA alkaline cells. 3
years typical domestic service life
Smoke detector
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 6V, 4 x AAA alkaline cells. 3
years typical domestic service life
Keyfob remote control
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 12 V , 23A/MN21 alkaline
miniature "lighter" battery. 3 years
typical domestic service life
Keypad remote control
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 3 x AAA alkaline cells. 3
years typical domestic service life
Help button
EMC Tested to EN 300 220-1 and ETS
300 683
Environmental conditions -10°C to
40°C, relative humidity 70% non-
condensing
Radio operational range 30m in a
typical domestic installation. Can vary
depending on building construction and
RF environment
Radio Microprocessor controlled
433.92MHz AM transmitter
Power supply 12V 23A/MN21 alkaline
miniature ‘lighter battery’. 3 years
typical domestic service life
0560
WEEE
Note: Waste electrical products should
not be disposed of with household
waste. Please recycle where facilities
exist. Check with your local authority or
retailer for recycling advice.
Yale
School Street, Willenhall,
West Midlands WV13 3PW
Tel: +44 (0) 1902 364606
Fax: +44 (0) 1902 364692
www.yale.co.uk
Pairing the door contact alarm with another
unit from the range
The standalone alarm range has been designed specifically
to operate as single units or be paired together to work as
kits.
Up to 3 of the master units those that have sensors as
well as sirens can be paired together. The number of
slave units those that do not have sensors that will
work together is limitless. This door contact alarm is a
master unit.
Each master unit has a unique radio code, which can be sent
to any other unit in order to make them work together.
The procedure for doing this is as follows:
1. Starting with any master unit which you want to be
the main teacher unit for the system
2. Enter your PIN code and then press the Yale button
afterward.
3. The LED will flash in the sequence green, orange, red
4. The unit is now in ‘sending’ mode for the next 2
minutes. The green
and orange
LED will flash every
second
5. Hold the rear metal
contact points of the
main unit against the
‘eyebrow’ contact
points of the learner
unit to which you are
pairing
6. To confirm the units
are paired, the
learner unit will have Red LED on constantly (indicates
units in contact) and will beep once afterward. Only
release after you hear this beep.
7. Repeat this contact for all other learner units you want
to pair with the teacher unit
8. After the 2 minutes ‘sending mode the main unit will
return to disarmed mode. The red LED will flash 3
times to confirm.
9. If you wish to exit the learning mode within the 2
minute duration, press CLR button twice on
the teacher unit to exit.
1
2
3
1
2
3
ARM
CLR
E1 09/08
Troubleshooting
The units red LED does not flash when the batteries are installed
Ensure the batteries are connected correctly according to the diagram
in the battery compartment.
The red light keeps flashing
This is the ‘low battery’ indicator. Replace the unit’s batteries.
Radio ON/OFF
The radio is default to be always on. It is possible to disable the radio function
if you are using just a single device in order to conserve power.
To turn ON radio: Enter your 4 digit PIN followed by “2, 1, 1, 1, 1”.
To turn OFF radio: Enter your 4 digit PIN followed by “2, Yale, Yale, Yale,
Yale”.
Factory reset
If you forget your PIN or the system malfunctions, you can press the reset
button (locates behind battery cover) to erase all memory. Please ensure the
device is powered and system is in Disarm mode. After reset you will need to
set-up your PIN again and pair with other devices (if required).
Battery precautions
When using this product follow these precautions at all times;
• Useonlytheappropriatesizebatteries
• Besuretofollowthecorrectpolaritywheninstallingthebatteriesas
indicated in the battery compartment. Incorrect polarity may cause
damage to the unit
• Donotmixoldandnewbatteries
• Ifthealarmisnotusedforlongperiodsoftime,removethebatteriesto
prevent damage to the unit or injury from possible battery leakage
• Donotrechargebatteriesnotintendedtoberecharged.Always
follow the manufacturers directions
Please only use alkaline batteries
Wireless range
If using as part of an extended system the range of these parts is a
minimum of 1 meter, up to a maximum of 25 meters.
System activity
Please note, when the red light is on the product is processing, so no
operation will work (for example, you will not be able to enter your PIN)