Datalogic SKORPIO Multi-Battery Charger Specifications

Download Quick start manual of Datalogic SKORPIO Multi-Battery Charger Battery Charger for Free or View it Online on All-Guides.com.

Datalogic SKORPIO Multi-Battery Charger Quick start manual - Page 1
1
DATALOGIC SKORPIO™
MULTI-BATTERY CHARGER
Figure 1
The Datalogic Skorpio™ Multi-Battery Charger, with its 4 slots,
allows you to charge the Datalogic Skorpio™ and Datalogic
Skorpio-GUN™ battery packs.
TECHNICAL FEATURES
ELECTRICAL
Power supply 12-14 VDC
Max consumption 4 A
Charge time
3 h 30 min Skorpio™
5 h min Skorpio-GUN™
PHYSICAL
Dimensions (LxWxH) 20 x 13.7 x 4.3 cm
(7.9 x 5.4 x 1.7 in)
Weight (without batteries) 687 g (24.2 oz)
LEDs 4 Charger Status LEDs
1 Power on LED
ENVIRONMENTAL
Working temperature 0° to +40 °C (+32° to +104 °F)
Storage temperature -20° to +70 °C (-4° to +158 °F)
Humidity 95% without condensation
Degree of protection IP30
CONNECTIONS
Plug the power supply into the connector positioned on the
Datalogic Skorpio™ Multi-Battery Charger base. Then plug the
power supply into a socket.
Figure 2
ACCESSORIES
94ACC4595 FPS18 power supply without power cord
94ACC1150 Power cord EU 3- pin
USING DATALOGIC SKORPIO™ MULTI-BATTERY CHARGER
Charge Function
Correctly insert the battery pack of the Datalogic Skorpio™ or
of the Datalogic Skoprio-GUN™ into one of the free slots:
simply press it into the slot until the battery latch is
automatically closed; charging starts automatically.
Figure 3
To remove the battery pack release the latch on the charger
for the Datalogic Skorpio™ and the latch on the gun battery
pack for the Datalogic Skorpio-GUN™ as indicated in figure 4:
Figure 4
Battery Charging Status LED Description
LED Status
Power Green It is constant when the
battery charger is powered
Charger Green Empty slot
Red Charging
Green Charge completed
Orange blinking Error
COMPLIANCE
FCC Compliance
Modifications or changes to this equipment without the
expressed written approval of Datalogic could void the
authority to use the equipment.
This device complies with PART 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
which may cause undesired operation.
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
822000761 (Rev. B)
Battery Charging State LEDs
Power on LED