Fabric OS MIB Reference 251
53-1001768-01
connUnitPortModuleType 1.3.6.1.3.94.1.10.1.9
8
• longwaveNoOFC (8)
• shortwaveNoOFC (9)
• longwaveLED (10)
• ssa (11) (Not supported in Fabric OS v2.6.1.)
For an external FC port, this value should be 9 (shortwaveNoOFC), 8 (longwaveNoOFC), or 6
(copper).
connUnitPortModuleType 1.3.6.1.3.94.1.10.1.9
The module type of the port connector.
Values Possible values are:
• unknown (1)
• other (2)
• gbic (3)
• embedded (4) Fixed (oneXnine)
• glm (5)
• gbicSerialId (6)
• gbicNoSerialId (7)
• gbicNotInstalled (8)
• smallFormFactor (9)
For an external FC port with GBIC, this value is set to 6 (gbicSerialId) or 7 (gbicNoSerialId). For an
external FC port without GBIC, this value is set to 8 (gbicNotInstalled).
connUnitPortWwn 1.3.6.1.3.94.1.10.1.10
The World Wide Name of the port, if applicable; otherwise, an empty string.
This is in IEEE Extended format, and the extension contains the internal port number of each port.
The internal port number is 1 less than the port index. For example, if the switch has WWN
10:00:00:60:69:10:02:18, then port numbers 0 and 6 have WWN 20:00:00:60:69:10:02:18 and
20:06:00:60:69:10:02:18, respectively. However, the embedded port has WWN
10:00:00:60:69:10:02:18, the same as the switch.
connUnitPortFCId 1.3.6.1.3.94.1.10.1.11
This is the assigned Fibre Channel ID of this port. This value is expected to be a Big Endian value of
24 bits. If this is a loop, then it is the AL_PA that is connected. If this is an E_Port, then it contains
the domain ID and area, left justified, 0 filled. If this port does not have a Fibre Channel address,
return all bits set to 1.
For an F_Port, this is the Fibre Channel ID to which the connected N_Port is assigned. For an
FL_Port, this is the Fibre Channel ID of the FL_Port. For a U or E_Port, this is similar to F_Port.