Fabric OS MIB Reference 277
53-1001768-01
connUnitEventTrap
8
Variables connUnitId
A connUnit has been deleted from this agent.
Recommended severity level (for filtering)- warning.
Not implemented.
connUnitEventTrap
Enterprise fcmgmt
Variables connUnitEventId, connUnitEventType, connUnitEventObject, connUnitEventDescr
An event has been generated by the connectivity unit.
Recommended severity level (for filtering)- info.
Sample trap output for Fabric OS v6.1.0.
connUnitEventId.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = 354
connUnitEventType.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = other(2)
connUnitEventObject.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = null
connUnitEventDescr.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = FW-1425
Switch status changed from MARGINAL to HEALTHY.
Refer to the “swEventTrap 1.3.6.1.4.1.1588.2.1.1.1.0.4” for more details.
connUnitSensorStatusChange
Enterprise fcmgmt
Variables connUnitSensorStatus
Overall status of the connectivity unit has changed.
This trap is generated whenever the status of the sensors (like fan, power supply, temperature)
present in the connectivity unit changes.
Sample trap output for Fabric OS v6.1.0.
connUnitSensorStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.7 = failed(5)
Refer to the Fabric Watch Administrator’s Guide for information on configuring thresholds that
generate these traps.
connUnitPortStatusChange
Enterprise fcmgmt
Variables connUnitPortStatus, connUnitPortState
Overall status of the connectivity unit changed. Recommended severity level (for filtering)- alert.
This trap sends the instance of connUnitPortName as part of the trap; the instance string is NULL,
if the port name is not defined for the specified port.