82 Fabric OS FCIP Administrator’s Guide
53-1001766-01
Portshow command usage
4
23 0 ge0 Disable ----s 0s 0.00 0.00 0 200/1000 0
23 1 ge1 Disable ----s 0s 0.00 0.00 0 200/1000 0
23 2 ge5 Disable ----s 0s 0.00 0.00 0 200/1000 0
23 3 ge4 Disable ----s 0s 0.00 0.00 0 200/1000 0
-------------------------------------------------------------------------------
Flags: tunnel: c=compression f=fastwrite t=Tapepipelining F=FICON T=TPerf
circuit: s=sack
Displaying FCIP tunnel information (7800 switch and FX8-24 blade)
The following example shows general tunnel information for a 7800 switch.
switch:admin> portshow fciptunnel 16
portshow fciptunnel 16
-------------------------------------------
Tunnel ID: 16
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: On (Moderate)
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Disabled
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:55:59:e9
Peer WWN: 10:00:00:05:1e:55:68:05
Circuit Count: 4
Flags: 0x00000000
FICON: Off
Displaying an FCIP tunnel with FCIP circuit information (7800 switch
and FX8-24 blade)
The following example adds circuit information to the fciptunnel output using the -c option.
switch:admin> portshow fciptunnel 17 -c
-------------------------------------------
Tunnel ID: 17
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: On (Moderate)
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Disabled
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:55:59:e9
Peer WWN: 10:00:00:05:1e:55:68:05
Circuit Count: 4
Flags: 0x00000000
FICON: Off
-------------------------------------------
Circuit ID: 16.0
Circuit Num: 0
Admin Status: Enabled