Dell PowerEdge M1000e Technical Manual

Download Technical manual of Dell PowerEdge M1000e Chassis, Computer Hardware for Free or View it Online on All-Guides.com.

Dell PowerEdge M1000e Technical manual - Page 1
1
Dell PowerEdge M1000e Technical manual - Page 2
2
Dell PowerEdge M1000e Technical manual - Page 3
3
Dell PowerEdge M1000e Technical manual - Page 4
4
Dell PowerEdge M1000e Technical manual - Page 5
5
Dell PowerEdge M1000e Technical manual - Page 6
6
Dell PowerEdge M1000e Technical manual - Page 7
7
Dell PowerEdge M1000e Technical manual - Page 8
8
Dell PowerEdge M1000e Technical manual - Page 9
9
Dell PowerEdge M1000e Technical manual - Page 10
10
Dell PowerEdge M1000e Technical manual - Page 11
11
Dell PowerEdge M1000e Technical manual - Page 12
12
Dell PowerEdge M1000e Technical manual - Page 13
13
Dell PowerEdge M1000e Technical manual - Page 14
14
Dell PowerEdge M1000e Technical manual - Page 15
15
Dell PowerEdge M1000e Technical manual - Page 16
16
Dell PowerEdge M1000e Technical manual - Page 17
17
Dell PowerEdge M1000e Technical manual - Page 18
18
Dell PowerEdge M1000e Technical manual - Page 19
19
Dell PowerEdge M1000e Technical manual - Page 20
20
Dell PowerEdge M1000e Technical manual - Page 21
21
Dell PowerEdge M1000e Technical manual - Page 22
22
Dell PowerEdge M1000e Technical manual - Page 23
23
Dell PowerEdge M1000e Technical manual - Page 24
24
Dell PowerEdge M1000e Technical manual - Page 25
25
Dell PowerEdge M1000e Technical manual - Page 26
26
Dell PowerEdge M1000e Technical manual - Page 27
27
Dell PowerEdge M1000e Technical manual - Page 28
28
Dell PowerEdge M1000e Technical manual - Page 29
29
Dell PowerEdge M1000e Technical manual - Page 30
30
Dell PowerEdge M1000e Technical manual - Page 31
31
Dell PowerEdge M1000e Technical manual - Page 32
32
Dell PowerEdge M1000e Technical manual - Page 33
33
Dell PowerEdge M1000e Technical manual - Page 34
34
Dell PowerEdge M1000e Technical manual - Page 35
35
Dell PowerEdge M1000e Technical manual - Page 36
36
Dell PowerEdge M1000e Technical manual - Page 37
37
Dell PowerEdge M1000e Technical manual - Page 38
38
Dell PowerEdge M1000e Technical manual - Page 39
39
Dell PowerEdge M1000e Technical manual - Page 40
40
Dell PowerEdge M1000e Technical manual - Page 41
41
Dell PowerEdge M1000e Technical manual - Page 42
42
Dell PowerEdge M1000e Technical manual - Page 43
43
Dell PowerEdge M1000e Technical manual - Page 44
44
Dell PowerEdge M1000e Technical manual - Page 45
45
Dell PowerEdge M1000e Technical manual - Page 46
46
Dell PowerEdge M1000e Technical manual - Page 47
47
Dell PowerEdge M1000e Technical manual - Page 48
48
Dell PowerEdge M1000e Technical manual - Page 49
49
Dell PowerEdge M1000e Technical manual - Page 50
50
Dell PowerEdge M1000e Technical manual - Page 51
51
Dell PowerEdge M1000e Technical manual - Page 52
52
Dell PowerEdge M1000e Technical manual - Page 53
53
Dell PowerEdge M1000e Technical manual - Page 54
54
Dell PowerEdge M1000e Technical manual - Page 55
55
Dell PowerEdge M1000e Technical manual - Page 56
56
Dell PowerEdge M1000e Technical manual - Page 57
57
Dell PowerEdge M1000e Technical manual - Page 58
58
Dell PowerEdge M1000e Technical manual - Page 59
59
Dell PowerEdge M1000e Technical manual - Page 60
60
Dell PowerEdge M1000e Technical manual - Page 61
61
Dell PowerEdge M1000e Technical manual - Page 62
62
Dell PowerEdge M1000e Technical manual - Page 63
63
Dell PowerEdge M1000e Technical manual - Page 64
64
Dell PowerEdge M1000e Technical manual - Page 65
65
Dell PowerEdge M1000e Technical manual - Page 66
66
Dell PowerEdge M1000e Technical manual - Page 67
67
Dell PowerEdge M1000e Technical manual - Page 68
68
Dell PowerEdge M1000e Technical manual - Page 69
69
Dell PowerEdge M1000e Technical manual - Page 70
70
Dell PowerEdge M1000e Technical manual - Page 71
71
39 PowerEdge M1000e Technical Guide
Figure 21. Grid redundancy
With power supply redundancy, the six power supplies are seen as one bank. They should be
populated in the following order: 1,2,3,4,5,6.
For information on the grid redundancy option, see the
Dell Chassis Management Controller
Firmware User's Guide
on Dell.com/Support/Manuals.
Supported redundancy options in CMC 3.0
Table 6 lists and the following sections describe the power supply redundancy options available in
CMC 3.0 for 1350W, 2700W, and 2360W power supplies.
Supported power supply redundancy options Table 6.
1350W
2700W
2360W
No redundancy
1+0
2+0
3+0
4+0
5+0
6+0
1+0
2+0
3+0
4+0
1+0
2+0
3+0
4+0
5+0
AC redundancy
1+1
2+2
3+3
1+1
2+2
3+3
1+1
2+2
3+3
Power supply
redundancy
1+1
2+1
3+1
4+1
5+1
1+1
2+1
3+1
4+1
1+1
2+1
3+1
4+1
5+1
Power tables for redundancy options
Table 7, Table 8 and Table 9 list the maximum power available for various power redundancy