Dell PowerEdge M420 Hardware Reference Manual

Download Hardware reference manual of Dell PowerEdge M420 Computer Hardware, Desktop for Free or View it Online on All-Guides.com.

Dell PowerEdge M420 Hardware reference manual - Page 1
1
Dell PowerEdge M420 Hardware reference manual - Page 2
2
Dell PowerEdge M420 Hardware reference manual - Page 3
3
Dell PowerEdge M420 Hardware reference manual - Page 4
4
Dell PowerEdge M420 Hardware reference manual - Page 5
5
Dell PowerEdge M420 Hardware reference manual - Page 6
6
Dell PowerEdge M420 Hardware reference manual - Page 7
7
Dell PowerEdge M420 Hardware reference manual - Page 8
8
Dell PowerEdge M420 Hardware reference manual - Page 9
9
Dell PowerEdge M420 Hardware reference manual - Page 10
10
Dell PowerEdge M420 Hardware reference manual - Page 11
11
Dell PowerEdge M420 Hardware reference manual - Page 12
12
Dell PowerEdge M420 Hardware reference manual - Page 13
13
Dell PowerEdge M420 Hardware reference manual - Page 14
14
Dell PowerEdge M420 Hardware reference manual - Page 15
15
Dell PowerEdge M420 Hardware reference manual - Page 16
16
Dell PowerEdge M420 Hardware reference manual - Page 17
17
Dell PowerEdge M420 Hardware reference manual - Page 18
18
Dell PowerEdge M420 Hardware reference manual - Page 19
19
Dell PowerEdge M420 Hardware reference manual - Page 20
20
Dell PowerEdge M420 Hardware reference manual - Page 21
21
Dell PowerEdge M420 Hardware reference manual - Page 22
22
Dell PowerEdge M420 Hardware reference manual - Page 23
23
Dell PowerEdge M420 Hardware reference manual - Page 24
24
Dell PowerEdge M420 Hardware reference manual - Page 25
25
Dell PowerEdge M420 Hardware reference manual - Page 26
26
Dell PowerEdge M420 Hardware reference manual - Page 27
27
Dell PowerEdge M420 Hardware reference manual - Page 28
28
Dell PowerEdge M420 Hardware reference manual - Page 29
29
Dell PowerEdge M420 Hardware reference manual - Page 30
30
Dell PowerEdge M420 Hardware reference manual - Page 31
31
Dell PowerEdge M420 Hardware reference manual - Page 32
32
Dell PowerEdge M420 Hardware reference manual - Page 33
33
Dell PowerEdge M420 Hardware reference manual - Page 34
34
Dell PowerEdge M420 Hardware reference manual - Page 35
35
Dell PowerEdge M420 Hardware reference manual - Page 36
36
Dell PowerEdge M420 Hardware reference manual - Page 37
37
Dell PowerEdge M420 Hardware reference manual - Page 38
38
Dell PowerEdge M420 Hardware reference manual - Page 39
39
Dell PowerEdge M420 Hardware reference manual - Page 40
40
Dell PowerEdge M420 Hardware reference manual - Page 41
41
Dell PowerEdge M420 Hardware reference manual - Page 42
42
Dell PowerEdge M420 Hardware reference manual - Page 43
43
Dell PowerEdge M420 Hardware reference manual - Page 44
44
Dell PowerEdge M420 Hardware reference manual - Page 45
45
Dell PowerEdge M420 Hardware reference manual - Page 46
46
Dell PowerEdge M420 Hardware reference manual - Page 47
47
Dell PowerEdge M420 Hardware reference manual - Page 48
48
M5424 SAN I/O Module Hardware Reference Manual 13
53-1001082-01
Connecting the SAN I/O Module to the Ethernet network
2
Connecting the SAN I/O Module to the Ethernet network
Once you have successfully set the appropriate IP address of the SAN I/O Module, you can
establish an Ethernet connection through the Chassis Management Controller (CMC) to a remote
management workstation for any additional configuration. The management workstation must be
on the same Ethernet subnet as the CMC.
NOTE
Ensure that the SAN I/O Module is not being modified from any other connection until configuration
is complete.
Connecting the SAN I/O Module to the fabric
NOTE
Refer to “Cabling guidelines” on page 8 before beginning the following procedure.
Before beginning the following steps, determine whether the SAN I/O Module is in Brocade Access
Gateway or Fabric OS Native mode. This affects the configuration process. Using the SAN I/O
Module CLI, enter the ag ––modeShow command to determine the current operating mode.
1. If the SAN I/O Module is in Fabric OS Native mode, continue with step 2 and step 3. If the
Module is in Access Gateway mode, go on to step 4.
2. Log onto the SAN I/O Module through a Telnet connection, using the admin account.
3. Modify the domain ID if required using SAN I/O Module CLI commands.
The default domain ID is 1. If the SAN I/O Module is not powered on until after it is connected
to the fabric and the default domain ID is already in use, the domain ID for the new SAN I/O
Module is automatically reset to a unique value. If the SAN I/O Module is connected to the
fabric after it has been powered on and the default domain ID is already in use, the fabric
segments.
To find the domain IDs that are currently in use, run the fabricShow command on another SAN
I/O Module or switch in the fabric. Identify an unused domain ID:
a. Disable the SAN I/O Module being configured using the switchDisable command.
b. Enter the configure command at the root prompt.
The command prompts display sequentially. Enter a new value at the Domain prompt or
press Enter to accept the default value. The SAN I/O Module now has a unique domain ID
and can join the fabric. Following is an example of command output.
Fabric parameters (yes, y, no, n): [no] y
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
Switch PID Format: (1..2) [1]Configure...
Domain: (1..239) [1] 155
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
WAN_TOV: (0..30000) [0]