York SPLIT-SYSTEM YHJD18 THRU 60 User Manual

Download Technical manual of York SPLIT-SYSTEM YHJD18 THRU 60 Air Conditioner, Heat Pump for Free or View it Online on All-Guides.com.

York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 1
1
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 2
2
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 3
3
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 4
4
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 5
5
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 6
6
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 7
7
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 8
8
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 9
9
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 10
10
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 11
11
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 12
12
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 13
13
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 14
14
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 15
15
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 16
16
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 17
17
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 18
18
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 19
19
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 20
20
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 21
21
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 22
22
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 23
23
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 24
24
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 25
25
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 26
26
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 27
27
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 28
28
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 29
29
York SPLIT-SYSTEM YHJD18 THRU 60 Technical manual - Page 30
30
TECHNICAL GUIDE
SPLIT-SYSTEM
HEAT PUMPS
13 SEER – R-22
MODELS:
Y
HJD18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)
Due to continuous product improvement, specifications
are subject to change without notice.
V
isit us on the web at www.york.com
A
dditional rating information can be found at
w
ww.ahridirectory.org
LISTED
ISO 9001
Certified Quality
Management System
398612-YTG-B-0608
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The heat pump condensing unit is the outdoor part of a versa-
tile system of heating and air conditioning. It is designed to be
custom-matched with one of UPG’s complete line of evapora-
tor sections, with each serving a specific function. Matching
Air Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-on coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of copper tubing and enhanced aluminum fins for
increased efficiency and corrosion protection.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This
is accomplished by the simultaneous operation of high
pressure relief valve and a temperature sensor which pro-
tects the compressor if undesirable operating conditions
occur. A liquid line filter-drier further protects the compres-
sor.
DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, and a single panel covering the electrical con-
trols make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.