Dell T420 Technical Manual

Download Technical manual of Dell External OEM Ready T420 Desktop, Processor for Free or View it Online on All-Guides.com.

Brand: Dell

Category: Desktop , Processor

Type: Technical manual for Dell External OEM Ready T420

Pages: 52 (1.64 Mb)

Download Dell External OEM Ready T420 Technical manual

Dell External OEM Ready T420 Technical manual - Page 1
1
Dell External OEM Ready T420 Technical manual - Page 2
2
Dell External OEM Ready T420 Technical manual - Page 3
3
Dell External OEM Ready T420 Technical manual - Page 4
4
Dell External OEM Ready T420 Technical manual - Page 5
5
Dell External OEM Ready T420 Technical manual - Page 6
6
Dell External OEM Ready T420 Technical manual - Page 7
7
Dell External OEM Ready T420 Technical manual - Page 8
8
Dell External OEM Ready T420 Technical manual - Page 9
9
Dell External OEM Ready T420 Technical manual - Page 10
10
Dell External OEM Ready T420 Technical manual - Page 11
11
Dell External OEM Ready T420 Technical manual - Page 12
12
Dell External OEM Ready T420 Technical manual - Page 13
13
Dell External OEM Ready T420 Technical manual - Page 14
14
Dell External OEM Ready T420 Technical manual - Page 15
15
Dell External OEM Ready T420 Technical manual - Page 16
16
Dell External OEM Ready T420 Technical manual - Page 17
17
Dell External OEM Ready T420 Technical manual - Page 18
18
Dell External OEM Ready T420 Technical manual - Page 19
19
Dell External OEM Ready T420 Technical manual - Page 20
20
Dell External OEM Ready T420 Technical manual - Page 21
21
Dell External OEM Ready T420 Technical manual - Page 22
22
Dell External OEM Ready T420 Technical manual - Page 23
23
Dell External OEM Ready T420 Technical manual - Page 24
24
Dell External OEM Ready T420 Technical manual - Page 25
25
Dell External OEM Ready T420 Technical manual - Page 26
26
Dell External OEM Ready T420 Technical manual - Page 27
27
Dell External OEM Ready T420 Technical manual - Page 28
28
Dell External OEM Ready T420 Technical manual - Page 29
29
Dell External OEM Ready T420 Technical manual - Page 30
30
Dell External OEM Ready T420 Technical manual - Page 31
31
Dell External OEM Ready T420 Technical manual - Page 32
32
Dell External OEM Ready T420 Technical manual - Page 33
33
Dell External OEM Ready T420 Technical manual - Page 34
34
Dell External OEM Ready T420 Technical manual - Page 35
35
Dell External OEM Ready T420 Technical manual - Page 36
36
Dell External OEM Ready T420 Technical manual - Page 37
37
Dell External OEM Ready T420 Technical manual - Page 38
38
Dell External OEM Ready T420 Technical manual - Page 39
39
Dell External OEM Ready T420 Technical manual - Page 40
40
Dell External OEM Ready T420 Technical manual - Page 41
41
Dell External OEM Ready T420 Technical manual - Page 42
42
Dell External OEM Ready T420 Technical manual - Page 43
43
Dell External OEM Ready T420 Technical manual - Page 44
44
Dell External OEM Ready T420 Technical manual - Page 45
45
Dell External OEM Ready T420 Technical manual - Page 46
46
Dell External OEM Ready T420 Technical manual - Page 47
47
Dell External OEM Ready T420 Technical manual - Page 48
48
Dell External OEM Ready T420 Technical manual - Page 49
49
Dell External OEM Ready T420 Technical manual - Page 50
50
Dell External OEM Ready T420 Technical manual - Page 51
51
Dell External OEM Ready T420 Technical manual - Page 52
52
46 PowerEdge T420 Technical Guide
Specification
Redundant
1100W
Redundant
750W
Redundant
495W
Non-redundant
550W
Maximum inrush
current
2
55A
55A
55A
55A
1
Auto-ranging
2
Under typical line conditions and over the entire system ambient operating range, the inrush current may reach
55A per power supply for 10ms or less.
Environmental specifications
Table 26 details the environmental specifications for the T420. For additional information about
environmental measurements for specific system configurations, see
Dell.com/environmental_datasheets.
Table 26. Environmental specifications
Fresh Air: temperature, humidity, altitude de-rating
Continuous
operation
10°C to 35°C (50°F to 95°F) at 10% to 80% relative humidity with 26°C (78.8°F) maximum
dew point (maximum wet bulb temperature). De-rate maximum allowable dry bulb
temperature at 1°C per 300m above 950m (1°F per 547 ft above 3117 ft).
Expanded
operation
When operating in the expanded temperature range, system performance may be impacted,
and ambient temperature warnings may be reported on the LCD and in the System Event
Log.
≤ 10% of annual operating hours: 5°C to 10°C and 35°C to 40°C (with no direct sunlight on
the equipment) at 5% to 85% relative humidity with 26°C dew point (maximum wet bulb
temperature). Outside the standard operating temperature (10°C to 35°C), the system can
operate down to 5°C or up to 40°C for a maximum of 10% of its annual operating hours. For
temperatures between 35°C and 40°C (95°F to 104°F), de-rate maximum allowable dry bulb
temperature by 1°C per 175m above 950m (1°F per 319 ft above 3117 ft).
≤ 1% of annual operating hours: 5°C to 5°C and 40°C to 45°C (with no direct sunlight on
the equipment) at 5% to 90% relative humidity with 26°C dew point (maximum wet bulb
temperature). Outside the standard operating temperature (10°C to 35°C), the system can
operate down to 5°C or up to 45°C for a maximum of 1% of its annual operating hours. For
temperatures between 40°C and 45°C (104°F to 113°F), de-rate maximum allowable dry bulb
temperature by 1°C per 125m above 950m (1°F per 228 ft above 3117 ft).
Expanded operation restrictions:
No cold startup below 5°C
Maximum altitude for the operating temperature must be 3050m (10,000ft)
Up to two redundant fans (back fans required)
Redundant PSU configuration required
Not supported:
GPU
LRDIMM
Peripheral cards not qualified by Dell