26 About Your System
E1116 Memory
disabled, temp
above range.
Power cycle
AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems." If the problem
persists, see "Getting
Help."
E1210 Motherboard
battery
failure. Check
battery.
CMOS battery is missing
or the voltage is outside of
the allowable range.
See "Troubleshooting the
System Battery."
E1211 RAID
Controller
battery
failure. Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See "Installing
a RAID Battery", and
"Troubleshooting System
Cooling Problems."
E1216 3.3V Regulator
failure.
Reseat PCIe
cards.
3.3V voltage regulator has
failed.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards."
E1229 CPU
#
VCORE
Regulator
failure.
Reseat CPU.
Specified processor
VCORE voltage regulator
has failed.
Reseat the processor(s).
See "Troubleshooting the
Processor(s)".
If the problem persists,
see "Getting Help."
E122A CPU
#
VTT
Regulator
failure.
Reseat CPU.
Specified processor VTT
voltage regulator has
failed.
Reseat the processor(s).
See "Troubleshooting the
Processor(s)".
If the problem persists,
see "Getting Help."
Table 1-1. LCD Status Messages (continued)
Code Text Causes Corrective Actions
book.book Page 26 Tuesday, September 15, 2009 10:08 AM