Dell 2970 Hardware Manual
Download Hardware owner's manual of Dell 2970 Server for Free or View it Online on All-Guides.com.
About Your System 23
E1421 CPU Init The system BIOS has reported a
processor initialization error.
See "Getting Help" on page 147.
E1422 CPU Machine Chk The system BIOS has reported a
machine check error.
See "Getting Help" on page 147.
E1610 PS # Missing No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.
See "Troubleshooting Power
Supplies" on page 122.
E1614 PS # Status No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.
See "Troubleshooting Power
Supplies" on page 122.
E1618 PS # Predictive Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.
See "Troubleshooting Power
Supplies" on page 122.
E161C PS # Input Lost Power source for specified power
supply is unavailable, or out of
acceptable range.
Check the AC power source for
the specified power supply. If the
problem persists, see
"Troubleshooting Power Supplies"
on page 122.
E1620 PS # Input Range Power source for specified power
supply is unavailable, or out of
acceptable range.
Check the AC power source for
the specified power supply. If the
problem persists, see
"Troubleshooting Power Supplies"
on page 122.
E1624 PS Redundancy The power supply subsystem is no
longer redundant. If the last
supply fails, the system will go
down.
See "Troubleshooting Power
Supplies" on page 122.
E1625 PS AC Current Power source is out of acceptable
range.
Check the AC power source.
E1710 I/O Channel Chk The system BIOS has reported an
I/O channel check.
See "Getting Help" on page 147.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions