Dell 1655MC Install Manual

Download Supplementary manual of Dell 1655MC Server for Free or View it Online on All-Guides.com.

Brand: Dell

Category: Server

Type: Supplementary manual for Dell 1655MC

Pages: 24 (1.79 Mb)

Download Dell 1655MC Supplementary manual

Dell 1655MC Supplementary manual - Page 1
1
Dell 1655MC Supplementary manual - Page 2
2
Dell 1655MC Supplementary manual - Page 3
3
Dell 1655MC Supplementary manual - Page 4
4
Dell 1655MC Supplementary manual - Page 5
5
Dell 1655MC Supplementary manual - Page 6
6
Dell 1655MC Supplementary manual - Page 7
7
Dell 1655MC Supplementary manual - Page 8
8
Dell 1655MC Supplementary manual - Page 9
9
Dell 1655MC Supplementary manual - Page 10
10
Dell 1655MC Supplementary manual - Page 11
11
Dell 1655MC Supplementary manual - Page 12
12
Dell 1655MC Supplementary manual - Page 13
13
Dell 1655MC Supplementary manual - Page 14
14
Dell 1655MC Supplementary manual - Page 15
15
Dell 1655MC Supplementary manual - Page 16
16
Dell 1655MC Supplementary manual - Page 17
17
Dell 1655MC Supplementary manual - Page 18
18
Dell 1655MC Supplementary manual - Page 19
19
Dell 1655MC Supplementary manual - Page 20
20
Dell 1655MC Supplementary manual - Page 21
21
Dell 1655MC Supplementary manual - Page 22
22
Dell 1655MC Supplementary manual - Page 23
23
Dell 1655MC Supplementary manual - Page 24
24
Replacing the Server Module Board 1-5
4 Select the Mirroring Properties Menu and press <Enter> to view or modify the
mirroring mode.
The two installed SCSI drives are listed with their SCSI IDs:
NOTE: SCSI ID 0 may be secondary and SCSI ID 1 may be primary in some cases.
5
Write down which SCSI ID is primary and which one is secondary.
6 Select the primary drive and press the space bar to change the Status field to No.
Repeat this step for the secondary drive.
NOTE: Both the primary and secondary Status fields should be No.
7 Press <Esc> to exit the Mirroring Properties Menu.
8 Select Save changes and exit this menu and then press <Enter>.
9 Press <Esc> to exit the Adapter Properties Menu.
10 Press <Esc> to exit the Main Menu.
11 Select Exit the Configuration Utility and press <Enter>.
The server module reboots. During POST, the two SCSI drives are displayed as
nonmirrored, as shown in the following example:
12 Go to "Replacing the Server Module Board."
SCSI ID Device
Identifier Mirrored Pair Status
0 Fujitsu MAN3184MP 5507 Primary
1 Fujitsu MAN3184MP 5A01 Secondary
HBA ID LUN VENDOR PRODUCT REV SYNC WIDE CAPACITY
0 0 0 Fujitsu MAN3184MP 5507 160.0 16 18211 MB
0 1 0 Fujitsu MAN3184MP 5A01 160.0 16 18211 MB
0 7 0 LSI Logic 1020/1030 1000c00 320.0 16