Appendix D: MIBs and SNMP Traps 238
30 Subsystem
upgrade failed.
Device ID: %s.
Informational The Remote Console Switch has detected a
special condition resulting in a failed
subsystem update. The condition has been
recorded is stored in the
dsTrapObjectFirmwareCondition object.
31 Warning
condition.
Device ID: %s.
Alarm condition:
%d. Alarm
description: %s.
Minor The Remote Console Switch has detected a
special condition to be trapped for warning
the operator. The condition indicates some
parameter outside of normal operation, such
as over temperature range. These are not
expected to result in unusual behavior, but
may be precursor to a subsequent urgent
condition.
32 Urgent
condition.
Device ID: %s.
Alarm condition:
%d. Alarm
description: %s.
Critical The Remote Console Switch has detected a
special condition to be trapped for alerting
the operator. The condition indicates some
parameter outside of normal operation that is
expected to result in unpredictable system
behavior.
33 User account
has been locked.
Client IP
Address: %s.
Locked user: %s.
Reason: %s.
Minor A user account has been locked.
The IP address of the client is contained in
dsTrapObjectIPAddress.
The name of the user who was locked is
contained in dsTrapObjectTargetUserName.
The reason for which the user account has
been locked is contained in
dsTrapObjectLockReason.
Trap
ID
Trap Message Severity Description