Delta 31-735 Instruction Manual

Download Instruction manual of Delta 31-735 Sander for Free or View it Online on All-Guides.com.

Brand: Delta

Category: Sander

Type: Instruction manual for Delta 31-735

Pages: 76 (2.7 Mb)

Download Delta 31-735 Instruction manual

Delta 31-735 Instruction manual - Page 1
1
Delta 31-735 Instruction manual - Page 2
2
Delta 31-735 Instruction manual - Page 3
3
Delta 31-735 Instruction manual - Page 4
4
Delta 31-735 Instruction manual - Page 5
5
Delta 31-735 Instruction manual - Page 6
6
Delta 31-735 Instruction manual - Page 7
7
Delta 31-735 Instruction manual - Page 8
8
Delta 31-735 Instruction manual - Page 9
9
Delta 31-735 Instruction manual - Page 10
10
Delta 31-735 Instruction manual - Page 11
11
Delta 31-735 Instruction manual - Page 12
12
Delta 31-735 Instruction manual - Page 13
13
Delta 31-735 Instruction manual - Page 14
14
Delta 31-735 Instruction manual - Page 15
15
Delta 31-735 Instruction manual - Page 16
16
Delta 31-735 Instruction manual - Page 17
17
Delta 31-735 Instruction manual - Page 18
18
Delta 31-735 Instruction manual - Page 19
19
Delta 31-735 Instruction manual - Page 20
20
Delta 31-735 Instruction manual - Page 21
21
Delta 31-735 Instruction manual - Page 22
22
Delta 31-735 Instruction manual - Page 23
23
Delta 31-735 Instruction manual - Page 24
24
Delta 31-735 Instruction manual - Page 25
25
Delta 31-735 Instruction manual - Page 26
26
Delta 31-735 Instruction manual - Page 27
27
Delta 31-735 Instruction manual - Page 28
28
Delta 31-735 Instruction manual - Page 29
29
Delta 31-735 Instruction manual - Page 30
30
Delta 31-735 Instruction manual - Page 31
31
Delta 31-735 Instruction manual - Page 32
32
Delta 31-735 Instruction manual - Page 33
33
Delta 31-735 Instruction manual - Page 34
34
Delta 31-735 Instruction manual - Page 35
35
Delta 31-735 Instruction manual - Page 36
36
Delta 31-735 Instruction manual - Page 37
37
Delta 31-735 Instruction manual - Page 38
38
Delta 31-735 Instruction manual - Page 39
39
Delta 31-735 Instruction manual - Page 40
40
Delta 31-735 Instruction manual - Page 41
41
Delta 31-735 Instruction manual - Page 42
42
Delta 31-735 Instruction manual - Page 43
43
Delta 31-735 Instruction manual - Page 44
44
Delta 31-735 Instruction manual - Page 45
45
Delta 31-735 Instruction manual - Page 46
46
Delta 31-735 Instruction manual - Page 47
47
Delta 31-735 Instruction manual - Page 48
48
Delta 31-735 Instruction manual - Page 49
49
Delta 31-735 Instruction manual - Page 50
50
Delta 31-735 Instruction manual - Page 51
51
Delta 31-735 Instruction manual - Page 52
52
Delta 31-735 Instruction manual - Page 53
53
Delta 31-735 Instruction manual - Page 54
54
Delta 31-735 Instruction manual - Page 55
55
Delta 31-735 Instruction manual - Page 56
56
Delta 31-735 Instruction manual - Page 57
57
Delta 31-735 Instruction manual - Page 58
58
Delta 31-735 Instruction manual - Page 59
59
Delta 31-735 Instruction manual - Page 60
60
Delta 31-735 Instruction manual - Page 61
61
Delta 31-735 Instruction manual - Page 62
62
Delta 31-735 Instruction manual - Page 63
63
Delta 31-735 Instruction manual - Page 64
64
Delta 31-735 Instruction manual - Page 65
65
Delta 31-735 Instruction manual - Page 66
66
Delta 31-735 Instruction manual - Page 67
67
Delta 31-735 Instruction manual - Page 68
68
Delta 31-735 Instruction manual - Page 69
69
Delta 31-735 Instruction manual - Page 70
70
Delta 31-735 Instruction manual - Page 71
71
Delta 31-735 Instruction manual - Page 72
72
Delta 31-735 Instruction manual - Page 73
73
Delta 31-735 Instruction manual - Page 74
74
Delta 31-735 Instruction manual - Page 75
75
Delta 31-735 Instruction manual - Page 76
76
5
Fig. A Fig. B
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
GROUNDED OUTLET BOX
GROUNDING MEANS
ADAPTER
POWER CONNECTIONS
A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a time delay fuse. NOTE: Time delay fuses should be marked “D” in Canada and “T” in the US. If
an extension cord is used, use only 3-wire extension cords which have 3-prong grounding type plugs and matching
receptacle which will accept the machine’s plug. Before connecting the machine to the power line, make sure the
switch (s) is in the “OFF” position and be sure that the electric current is of the same characteristics as indicated on the
machine. All line connections should make good contact. Running on low voltage will damage the machine.
Do not expose the machine to rain or operate the machine in damp locations.
MOTOR SPECIFICATIONS
Your machine is wired for 240, or 200/230/460 volt, 60 HZ alternating current. Before connecting the machine to the
power source, make sure the switch is in the “OFF” position.
GROUNDING INSTRUCTIONS
This machine must be grounded while in use to protect the operator from electric shock.
1. All grounded, cord-connected machines:
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is equipped with an electric cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician.
Improper connection of the equipment-grounding conductor can result in risk of electric shock. The conductor with
insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor.
If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor
to a live terminal.
Check with a qualified electrician or service personnel if the grounding instruction are not completely understood, or
if in doubt as to whether the machine is properly grounded.
Use only 3-wire extension cords that have 3-prong grounding type plugs and matching 3-conductor receptacles that
accept the machine’s plug, as shown in Fig. A.
Repair or replace damaged or worn cord immediately.
2. Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating less than
150 volts:
If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A, the
machine will have a grounding plug that looks like the plug illustrated in Fig. A. A temporary adapter, which looks like
the adapter illustrated in Fig. B may be used to connect this plug to a matching 2-conductor receptacle as shown
in Fig. B, if a properly grounded outlet is not available. The temporary adapter should be used only until a properly
grounded outlet can be installed by a qualified electrician. The green-colored rigid ear, lug, and the like, extending
from the adapter must be connected to a permanent ground such as a properly grounded outlet box. Whenever the
adapter is used, it must be held in place with a metal screw.
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.
In all cases, make certain that the receptacle in question is properly grounded. If you are not sure,
have a qualified electrician check the receptacle.