READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFEGUARDS
CAUTION : To reduce the risk of fire and to properly exhaust air, be
sure to duct air outside. Do not vent exhaust air into spaces within
walls or ceilings or into attics, crawl spaces, or garages.
WARNING: To reduce the risk of fire or electric shock, do not use
this fan with any solid-state speed control device.
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
OR INJURY TO PERSONS OBSERVE THE FOLLOWING.
a) Use this unit only in the manner intended by the manufacturer. If
you have any questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power to off at
service panel, and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
CAUTION - For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If
you have any questions, please contact the manufacturer.
b) Before servicing or cleaning unit, switch power to off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
c) Installation work and electrical wiring must be done by qualified,
competent, trained person(s) in accordance with all applicable
codes and standards using proper safety practices, including fire-
related construction.
d) When cutting or drilling into a wall or
ceiling, ALWAYS identify hidden electrical
wiring and other hidden utilities in advance,
to avoid damage.
g) Ducted fans must always be vented to
the outdoors.
f) Do not install in cooking area.
Caution: For general use only. Do not use to
exhaust hazardous or explosive materials
or vapours.
This fan is designed to mount between
exterior walls 4-1/2" to 9-1/2" in thickness.
The exterior wall cap is to be mounted to
1 x 2" frame (casing) secured to the
exterior wall. If the exterior wall sheathing
is not plywood you will be required to add
support and secure the frame (casing) &
exterior wall cap. (fig 1)
BEGINNING THE
INSTALLATION
Remove the motor bracket assembly
(which includes the bracket / fan motor
/ & blade) from the fan housing. Loosen
the 2 screws which secure the bracket in
place – Once loosened enough carefully
maneuver the motor bracket so the
screw heads clear the keyhole slots.
Carefully remove the motor bracket
assembly and place it where it will not
get damaged. Remove the inner
housing from the outer housing (it is
slide in place). Along with the fan will
be packaged the wiring compartment,
and wiring compartment cover & motor
receptacle, along with 2 mounting
screws.
MOUNTING THE HOUSING
Choose the best location to mount the
housing on an interior wall. Make sure
there are no studs, or electrical/
mechanical utilities where you have
selected.
1. Once you have selected the best
location on the interior of the house
transfer that location to the outside of
the house and check that there are no
obstructions / and clearance for the fan
to operate properly.
2. Once the installation has been checked cut a 8-1/4" dia hole in
the interior wall where the fan is to be located.
3. Drill a small hole through to the outside in the center of the
8-1/4" dia hole so you can properly locate the exterior wall cap.
4. On the siding of the outside wall layout a 14-1/2" x 14-1/2"
square with the small hole (drill in step 3) in the center. (fig 2)
5. Cut out the square hole. – ONLY CUT THE EXTERIOR WALL
SIDING DO NOT CUT THE SHEATHING UNDERNEATH. (fig 3)
6. Once the siding is cut nail down all the loose ends of the siding.
7. In the center of the 14 -1/2" square mark and cut a 8 -1/4" dia
hole in the wall sheathing.
8. Install 1" x 2" casing
strips for support on
edges of the 14 -1/2"
square hole. These casing
strips are to be secured to
plywood sheathing via
screws or nails. If
sheathing is not plywood
you will have to add
support. (fig 4)
9. On the interior flange of
the wall cap apply a
generous amount of
caulking.
EWF180
14-1/2
14-1/2
Figure 1
Figure 2
Figure 3
AIR KING LIMITED, 110 GLIDDEN ROAD, BRAMPTON, ONTARIO, CANADA; TEL. 905-456-2033, 1-800-465-7300, FAX. 905-456-1015
Figure 4
Figure 5
Figure 6
Nail loose ends
1"x2" casing frame
8-1/4"
diameter
hole
Seal edges
with caulk
Bead of
caulking
Electrical compartment
clearance knockout
Electrical
compartment
cover
Electrical compartment
Electrical
compartment
clearance
Interior fan housing
Fan ground