DUALBRITE
®
Motion Sensor
Light Control
Model SH-5597
Features
DUALZONETechnology.
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
DUALBRITE
®
Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
2 Wire
Connectors
Gasket
6 Screws
(3 sizes included)
Light Control
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Override, the control must
be wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with a junction box
marked for use in wet locations.
Mounting Strap
Mounting Bolt
2 Lamps
(installed)
OPERATION
* resets to Auto Mode at dawn.
TEST
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to
Dawn
DUALBRITE
®
Put ON-TIME switch
on the sensor bottom
to TEST and the DUAL-
BRITE
®
switch OFF.
MANUAL MODE
ON-TIME
TEST 1 5 20
... back on.
AUTO
1 Second OFF
then...
DUALBRITE
®
TIMER
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the
light turns on full bright for the ON-TIME (1, 5, or 20
minutes) then returns to dim mode.
Move ON-TIME Switch to
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
Note: When first turned on wait about 1
1
/
2
minutes
for the circuitry to calibrate.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali
-
bration time the control will be in the AUTO mode.
Rubber Plug
Plastic Hanger
Cover
Plate
Sensor
Lamp
Holders
This package includes:
Put the ON-TIME switch in the 1,
5, or 20 minute position.
Mode: On-Time: Works: Day Night
Test 5 Sec x x
Auto 1, 5, 20 min. x
Manual Until Dawn* x