VSP-V-1118
Issue 5
1 947118
V-1118
ALL CALL UNIT
INTRODUCTION
The V-1118 All Call Unit is a compact,
self-contained unit designed to be used in
conjunction with the V-119RTVA and V-119RTHF
intercom units to provide an all call feature.
This equipment has received FCC type KX
registration, designed to be used with FCC registered
Key Telephone Systems. In accordance with FCC
Rules with applicable tariffs, this Paging unit may be
installed with the authorization of the host system.
Installations may be made by Valcom, Inc., an
authorized agent of the same, equipment
manufacturers, telephone companies, registered
telephone refurbishers, and those qualified for
installation of FCC registered systems under FCC
Rules Section 68.215.
The FCC Registration Number,
BAFUSA-69358-KX-N, will be listed in the
affidavits filed with the telephone company; it will
also be recorded in the system log kept by installation
and maintenance personnel. The local telephone
company is to be notified of the FCC Registration
Number when this Paging Unit is installed.
NOMINAL SPECIFICATIONS
Power to Speakers: 400 mW
Current at 24Vdc: 500mA during operation
Temperature range: 0 to 50 C
Dimensions: 7.13" H x 5.75" W x 2.13" D
(18.11cm H x 14.61cm W x 5.41cm D)
INSTALLATION
Mount the V-1118 unit within easy access distance of
the intercom unit being used (cable is 30" length).
Remove fuses or turn off power source before
connecting or disconnecting any cables or leads.
Remove connector from existing ICM unit and
connect to plug on all call unit marked speaker.
Connect one end of the 22 foot connectorized cable
to plug of all call unit marked ICM and the other end
to plug on existing ICM unit (See Figure 1).
If any stations are to be excluded, refer to Figure 2.
Verify all connections before restoring power to
system.
OPERATION
When calling party dials 29, the intercom switching
network closes contacts for station 29. Ground,
present at connector pins 29-46 and 50 of the V-1118,
supplies current through the intercom which returns
to pin 22 of the V-1118. The current into pin 22
reaches an RC network. After a delay of
approximately one second, all relays activate. The
relays provide an audio path for the calling party. The
one second delay essentially deletes the alert tone
from the V-119 on all call. Strapping pins 48 and 47
together on the 66 block inhibits the one second delay
and allows alert tone over the speakers during all call.
TECHNICAL ASSISTANCE
If the all call feature does not work, verify plug
connections. If connections are correct, verify ICM
unit is operating properly by removing plug from the
speaker side of the V-1118 and connecting to the
ICM unit. If the ICM unit operates properly, reverse
plugs on the V-1118.