Wayne 332200-001 Important Safety Instructions Manual

Download Operating instructions & parts manual of Wayne 332200-001 Household Appliance for Free or View it Online on All-Guides.com. This version of Wayne 332200-001 Manual compatible with such list of devices, as: 332200-001, SEP4, SEP5, SEP6, SEP8

Brand: Wayne

Category: Household Appliance

Type: Operating instructions & parts manual

Model: Wayne 332200-001 , Wayne SEP4 , Wayne SEP5 , Wayne SEP6 , Wayne SEP8

Pages: 8 (0.92 Mb)

Download Wayne 332200-001 Operating instructions & parts manual

Wayne 332200-001 Operating instructions & parts manual - Page 1
1
Wayne 332200-001 Operating instructions & parts manual - Page 2
2
Wayne 332200-001 Operating instructions & parts manual - Page 3
3
Wayne 332200-001 Operating instructions & parts manual - Page 4
4
Wayne 332200-001 Operating instructions & parts manual - Page 5
5
Wayne 332200-001 Operating instructions & parts manual - Page 6
6
Wayne 332200-001 Operating instructions & parts manual - Page 7
7
Wayne 332200-001 Operating instructions & parts manual - Page 8
8
Sewer Ejector
Pump
Description
The submersible pump is designed
for home applications. The unit is
equipped with a 3-prong grounding
type power cord. Motor is oil-filled and
sealed for cooler running and designed
to operate under water. This pump is
not suitable for aquatic life, ponds or
fountains.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Important Safety
Instructions
READ AND FOLLOW ALL INSTRUCTIONS
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
GENERAL SAFETY INFORMATION
Do not
use to
pump fl ammable or explosive
uids such as gasoline, fuel
oil, kerosene, etc. Do not
use in a fl ammable and/or explosive
atmosphere. Personal injury and/or
property damage could result.
This pump is
not designed
to handle salt water, brine, laundry
discharge or any other application
which may contain caustic chemicals
and/or foreign materials. Pump damage
could occur if used in these applications
and will void warranty.
All wiring must be
performed by a
qualifi ed electrician.
If
the
basement has water or
moisture on the fl oor, do not
walk on wet area until all
power is turned off. If the shut-off box
is in the basement, call an electrician.
Remove pump and either repair or replace.
Failure to follow this warning could result
in fatal electrical shock.
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols:
Danger indicates an
imminently
hazardous situation which, if not avoided,
WILL result in death or serious injury.
Warning indicates a
potentially
hazardous situation which, if not avoided,
COULD result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, MAY
cause damage to equipment.
General Safety
Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
Specifications
Power supply requirements
SEP4 . . . . . . . . . . . . . . . . . . . . . . . . 120V, 60 hz
SEP5, SEP6, and SEP8 . . . . . . . . . . 240V, 60 hz
Motor . . . . . . . . . . . . . . . . . . . . . . . . Single phase, oil filled
Horsepower/Current
SEP4 . . . . . . . . . . . . . . . . . . . . . . . . 1/2 HP, 12A @ 115VAC
SEP5 . . . . . . . . . . . . . . . . . . . . . . . . 3/4 HP, 7A @ 230VAC
SEP6 . . . . . . . . . . . . . . . . . . . . . . . . 1 HP, 8.5A @ 230VAC
SEP8 . . . . . . . . . . . . . . . . . . . . . . . . 2 HP, 12A @ 230VAC
Liquid temperature range . . . . . . . 40°F to 120°F
Circuit requirements . . . . . . . . . . . . 15 amps (min)
Dimensions. . . . . . . . . . . . . . . . . . . . . . 11 1/2 in. high x 9 3/4 in. base
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure to
comply with instructions could result in personal injury and/or property damage! Retain instructions for future
reference.
For parts, product & service information
visit www.waynepumps.com
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
332200-001 2/09
Operating Instructions & Parts Manual
SEP4, SEP5,
SEP6 and SEP8
© 2009 Wayne Water Systems
Construction
Motor housing . . . . . . . . . . . Cast Iron
Volute . . . . . . . . . . . . . . . . . . Cast Iron
Impeller . . . . . . . . . . . . . . . . . Cast Iron
Shaft . . . . . . . . . . . . . . . . . . . Low carbon steel
Seals . . . . . . . . . . . . . . . . . . . . Buna N
Discharge . . . . . . . . . . . . . . . 3 in. NPT
2 in. NPT (Adapter included)