Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8
Output Label
XW12a LF XW12a HF XW12a LF XW12a HF XW12a LF XW12a HF XW12a LF XW12a HF
Output Delay 270.83us 0s 270.83us 0s 270.83us 0s 270.83us 0s
Polarity Invert no no no no no no no no
Output Gain 0dB -9dB 0dB -9dB 0dB -9dB 0dB -9dB
HP Filte
r
Type BW24 LR24 BW24 LR24 BW24 LR24 BW24 LR24
Frequency 59.1Hz 1.5kHz 59.1Hz 1.5kHz 59.1Hz 1.5kHz 59.1Hz 1.5kHz
LP Filte
r
Type LR24 BW12 LR24 BW12 LR24 BW12 LR24 BW12
Frequenc
y
1.5kHz 18.2kHz 1.5kHz 18.2kHz 1.5kHz 18.2kHz 1.5kHz 18.2kHz
All-Pass Filte
r
Frequency
Slope
off off off off off off off off
Q
Filter 1
Filter Type Loshelf PEQ Loshelf PEQ Loshelf PEQ Loshelf PEQ
Frequency 182Hz 2.42kHz 182Hz 2.42kHz 182Hz 2.42kHz 182Hz 2.42kHz
Slope/Q 12dB 4.8 12dB 4.8 12dB 4.8 12dB 4.8
Gain 2.7dB 4dB 2.7dB 4dB 2.7dB 4dB 2.7dB 4dB
Filter 2
Filter Type PEQ PEQ PEQ PEQ PEQ PEQ PEQ PEQ
Frequency 315Hz 6.3kHz 315Hz 6.3kHz 315Hz 6.3kHz 315Hz 6.3kHz
Q 3.6 4.8 3.6 4.8 3.6 4.8 3.6 4.8
Gain -4dB -2dB -4dB -2dB -4dB -2dB -4dB -2dB
Filter 3
Filter Type PEQ PEQ PEQ PEQ PEQ PEQ PEQ PEQ
Frequency 879Hz 18.2kHz 879Hz 18.2kHz 879Hz 18.2kHz 879Hz 18.2kHz
Q 2.87 1.41 2.87 1.41 2.87 1.41 2.87 1.41
Gain -2dB 3dB -2dB 3dB -2dB 3dB -2dB 3dB
Filter 4
Filter Type
Frequency
Q
Gain
Filter 5
Filter Type
Frequency
Q
Gain
Filter 6
Filter Type Hishelf Hishelf Hishelf Hishelf
Frequency 8kHz 8kHz 8kHz 8kHz
Slope/Q 12dB 12dB 12dB 12dB
Gain 6dB 6dB 6dB 6dB
Compressor
Threshold (dBu)
Ratio (N to 1)
Insert (In/Out)
out out out out out out out out
Attack (us)
Release (ms)
Knee (Hard/Soft)
Limiter
Threshold (dBu) 0dBu -2dBu 0dBu -2dBu 0dBu -2dBu 0dBu -2dBu
Release (ms) 100ms 3ms 100ms 3ms 100ms 3ms 100ms 3ms
XW12a DN9848(e) P3000 0dBu V2_0
Output levels and limiter settings assume equal amplifier power to each passband with amplifier input sensitivity of 0dBu
Notes: DN9848e and DN9848 with firmware V4.01 and higher have the ability to toggle between Q and BW for parametric filters. DN9848
with firmware V3.05 and older only use BW, use attached conversion spreadsheet to convert. Do not adjust output filters, use input filters for
room and system tuning. DN9848 with firmware V3.05 and older has a maximum of 100ms release time for limiters. For these versions,
change Subwoofer and LF release times to 100ms.