A.O. Smith 120-Gallon Specification Sheet

Download Submittal sheet of A.O. Smith 120-Gallon Water Heater for Free or View it Online on All-Guides.com.

Brand: A.O. Smith

Category: Water Heater

Type: Submittal sheet

Model: A.O. Smith 120-Gallon , A.O. Smith 40-Gallon

Pages: 1 (0.46 Mb)

Download A.O. Smith 120-Gallon Submittal sheet

A.O. Smith 120-Gallon Submittal sheet - Page 1
1
SUGGESTED SPECIFICATIONS
Maximum kW Input - All Residential
44
0-120 Gallon Models
elbaliavA tupnI Wk mumixaMgniriWegatloVsledoM
All 40-Gallon to
120-Gallon Models
120v
——————
——————
208v
240v
- Not Available
** Simultaneous wiring not available-exceeds allowable amperage draw
SELF-CLEANING RESIDENTIAL ELECTRIC WATER
HEATERS SUBMITTAL SHEET
277
480
1500w, 2500w,
4500w, 6000w
1500w, 2500w,
4500w, 6000w
2500w, 4500w,
6000w
2500w, 4500w,
6000w
1650w &
2500w
1650w &
2500w
1000w, 1500w
2500w, 3000w
3500w, 4000w
4500w, 5500w
& 6000w
1000w, 1500w
2500w, 3000w
3500w, 4000w
4500w, 5500w
& 6000w
1500w, 2000w
3000w, 3800w
4500w, 5500w
& 6000w
1500w, 2000w
3000w, 3800w
4500w, 5500w
& 6000w
Some wattages are only available in incoloy.
Residential Electric Water Heaters
1.65
3.3
——
3.8
7.6
Page 1 of 1
AOSRE63000
Created September 2008
This water heater(s) shall be A. O. Smth Model(s) No. _____________________ electric heater, or an approved equal. Heater(s) shall be rated at ______ kW,
____Volts, _____ Cycle AC and listed by Underwriters’ Laboratories. Heater(s) shall have a maximum working pressure of 150 psi, a nominal storage tank
capacity of ______ gallons with a separate 3/4” tapping for relief valve installation. Unit shall include a rigidly supported anode rod for maximum cathodic
prote ction. Anode rod shall be constructed of ______________ material. All internal surfaces of the heater(s) exposed to water shall be coated with a glass
lining composition that is fused to the tank steel. Electric heating elements shall be ____________, screw-in design. Element operation shall be double element,
non-simultaneous (unless ordered differently). The controls shall include a thermostat with each element and a high temperature cutoff. The jacket shall provide full
size control compartments for performance of service and maintenance through front panel openings and enclose the tank with foam insulation. The drain valve
shall be located in the front for ease of service. Outer jacket shall be an enamel type finish. Heater(s) shall have a ____ year limited warranty for residential
installations;____ year commercial installations as outlined in the written warranty. Fully illustrated instruction manual to be included. Code Compliance: Meets
or exceeds Federal minimum energy standards according to the latest edition of the National Appliance Energy Conservation Act (NAECA). Also complies
with ASHRAE 90.1-2004 and current editions of ICC Code and HUD Standards.
Element Wattage & Voltage Table