Viking Designer DGCU165 Specifications

Download Specifications of F-SECURE CLIENT SECURITY 9.10 - S Accessory, Cooktop for Free or View it Online on All-Guides.com. This version of F-SECURE CLIENT SECURITY 9.10 - S Manual compatible with such list of devices, as: CLIENT SECURITY 9.10 - S, DGCU105, DGCU165, DGSU100, VGSU102

F-SECURE CLIENT SECURITY 9.10 - S Specifications - Page 1
1
F-SECURE CLIENT SECURITY 9.10 - S Specifications - Page 2
2
F-SECURE CLIENT SECURITY 9.10 - S Specifications - Page 3
3
F-SECURE CLIENT SECURITY 9.10 - S Specifications - Page 4
4
F-SECURE CLIENT SECURITY 9.10 - S Specifications - Page 5
5
F-SECURE CLIENT SECURITY 9.10 - S Specifications - Page 6
6
2
DESCRIPTION DGCU105 (30” W.) DGCU165 (36” W.) DGCU155 (45” w.)
Cutout Width - Minimum 28 3/4” (73.0 cm) 34 1/2” (87.6 cm) 42 7/8” (108.9 cm)
Maximum 29 7/8” (75.9 cm) 35 7/8” (91.1 cm) 44 1/8” (112.1 cm)
Cutout Height - Minimum 2 3/4” (7.0 cm)
Cutout Depth - Minimum 19 11/16” (50.0 cm)
Maximum 20 1/2” (52.1cm)
Overall Width 30 3/4” (78.1 cm) 36 3/4” (93.3 cm) 45” (114.3 cm)
Overall Height from Bottom
(including connector) 4 1/4” (10.8 cm)
Overall Depth from Rear 21” (53.3 cm)
Gas Requirements Not field convertible - Must be ordered from factory either natural or LP/Propane.
Uses
standard residential 1/2” (1.3 cm) I.D. gas service line.
Electrical Requirements 120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.
Maximum Amp Usage 2.0 amps
Surface Burner Rating
Left Front- 14,000 Nat./13,500 LP (BTU) 12,000 Nat./11,500 LP (BTU) 12,000 Nat./11,500 LP (BTU)
(4.1 Nat./4.0 LP [kw]) (3.5 Nat./2.8 LP [kw]) (3.5 Nat./2.8 LP [kw])
Left Rear- 12,000 Nat./11,500 LP (BTU) 10,000 Nat./LP (BTU) 8,000 Nat./LP (BTU)
(3.5 Nat./2.8 LP [kw]) (2.9 Nat./LP [kw]) (2.1 Nat./LP [kw])
Left Center N/A 14,000 Nat./13,500 LP (BTU) 10,000 Nat./LP (BTU)
(4.1 Nat./4.0 LP [kw]) (2.9 Nat./LP [kw])
Right Center N/A N/A 14,000 Nat./13,500 LP (BTU)
(4.1 Nat./4.0 LP [kw])
Right Rear- 8,000 Nat./LP (BTU) 8,000 Nat./LP (BTU) 6,000 Nat./LP (BTU)
(2.1 Nat./LP [kw]) (2.1 Nat./LP [kw]) (1.8 Nat./LP [kw])
Right Front- 6,000 Nat./LP (BTU) 6,000 Nat./LP (BTU) 8,000 Nat./LP (BTU)
(1.8 Nat./LP [kw]) (1.8 Nat./LP [kw]) (2.1 Nat./LP [kw])
Approximate Shipping Weight 67 lb. (30.2 kg.) 80 lb. (36.0 kg) 93 lb. (41.9 kg)
DESCRIPTION VGSU102 (30” W.) VGSU162 (36” W.)
Cutout Width - Minimum 26 7/8” (68.3 cm) 34 3/8” (87.3 cm)
Maximum 29 7/8” (75.9 cm) 35 7/8” (91.1 cm)
Cutout Height - Minimum 2 1/2” (6.4 cm)
Cutout Depth - Minimum 18 5/8” (47.3 cm)
Maximum 20 1/8” (51.1cm)
Overall Width 30 3/4” (78.1 cm) 36 3/4” (93.3 cm)
Overall Height from Bottom 5” (12.7 cm)
Overall Depth from Rear 21” (53.3 cm)
Gas Requirements To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed. Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP.
Uses standard residential 1/2” (1.3 cm) I.D. gas service line.
Electrical Requirements 120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.
Maximum Amp Usage 2.0 amps
Surface Burner Rating
Left Front- 16,000 Nat./15,500 LP (BTU) 16,000 Nat./15,500 LP (BTU)
(4.8 Nat./4.65 LP [kw]) (4.8 Nat./4.65 LP [kw])
Left Rear- 12,000 Nat./11,500 LP (BTU) 12,000 Nat./11,500 LP (BTU)
(3.6 Nat./3.45 LP [kw]) (3.6 Nat./3.45 LP [kw])
Center Front/Rear N/A 12,000 Nat./11,500 LP (BTU)
(3.6 Nat./3.45 LP [kw])
Right Rear- 8,000 Nat./7,500 LP (BTU) 8,000 Nat./7,500 LP (BTU)
(2.4 Nat./2.25 LP [kw]) (2.4 Nat./2.25 LP [kw])
Right Front- 6,000 Nat./5,500 LP (BTU) 6,000 Nat./5,500 LP (BTU)
(1.8 Nat./1.65 LP [kw]) (1.8 Nat./1.65 LP [kw])
Approximate Shipping Weight 67 lb. (30.2 kg.) 80 lb. (36.0 kg)
BASIC SPECIFICATIONS