Viking E-1600A-BLT-EWP User Manual

Download Technical practice of Viking TBB-1 Battery Charger, Emergency Phone for Free or View it Online on All-Guides.com. This version of Viking TBB-1 Manual compatible with such list of devices, as: TBB-1, E-1600A-BLT-EWP, E-1600A-BLT2-EWP, PB-100

Viking TBB-1 Technical practice - Page 1
1
Viking TBB-1 Technical practice - Page 2
2
Viking TBB-1 Technical practice - Page 3
3
Viking TBB-1 Technical practice - Page 4
4
Viking TBB-1 Technical practice - Page 5
5
Viking TBB-1 Technical practice - Page 6
6
Viking TBB-1 Technical practice - Page 7
7
Viking TBB-1 Technical practice - Page 8
8
Viking TBB-1 Technical practice - Page 9
9
Viking TBB-1 Technical practice - Page 10
10
Viking TBB-1 Technical practice - Page 11
11
Viking TBB-1 Technical practice - Page 12
12
Many new building codes require emergency communication in elevators and “Area
of Refuge” sites. Now you can provide added safety for your patrons, employees,
and students with the addition of high visibility, ADA Compliant emergency commu-
nication. At the simple push of a button, the E-1600A-BLT-EWP will initiate a call to
your emergency personnel and send a digital announcement to identify the location
of the emergency call. In addition, the tower phone’s bright (1million candle power)
strobe light will instantly begin flashing to deter further activity and make it fast and
easy for Police or Security personnel to locate the site of the emergency.
Though the strobe requires external power to operate, rest assured that communi-
cation is possible, even during power failures! All phone numbers, location num-
bers and programming parameters are stored in non-volatile memory. No batteries
are required to hold the memory.
The E-1600A-BLT-EWP and E-1600A-BLT2-EWP are equipped for outdoor or
harsh environments with Enhanced Weather Protection (EWP). EWP features rub-
ber gaskets and boots, hand soldered silicon sealed connections, gel filled butt con-
nectors, as well as urethane potted circuit boards with internally sealed, field-
adjustable trim pots and DIP switches for easy on-site programming.
P
P
r
r
a
a
c
c
t
t
i
i
c
c
e
e
T
T
E
E
L
L
E
E
C
C
O
O
M
M
S
S
O
O
L
L
U
U
T
T
I
I
O
O
N
N
S
S
F
F
O
O
R
R
T
T
H
H
E
E
2
2
1
1
S
S
T
T
C
C
E
E
N
N
T
T
U
U
R
R
Y
Y
Phone Power: Telephone line powered. Minimum 24V DC talk battery
voltage, with a minimum loop current of 20mA. Loop current may be
boosted on low current lines with a Viking Model TBB-1 talk battery
booster (Fax Back # 630).
Strobe Power: 120V AC/12V DC power adapter (included)
Maximum Strobe Power Run: 200 feet using 24 awg wire
Dimensions: 1070mm x 152.4mm x 109.3mm (42” x 6” x 4.5”)
Shipping Weight: 9.1 kg (20 lbs)
Mounting: Surface mount to rigid wall or post
Environmental: -26°C to 54°C (-15°F to 130°F) with 5% to 95%
non-condensing humidity
Strobe Output: 1,000,000 candle power
Material: Enclosure - .125 aluminum, 76.2mm x 152.4mm (3” x
6”) tube, powder painted high-visible yellow, Phone - .074 (14
gauge) stainless steel with stainless steel button, Strobe - Vandal
resistant polycarbonate plastic
Connections: Color-coded wires with gel-filled butt connectors
• Campus Security Sites
Area of Refuge sites
• Parking Ramps/Lots
Automated Tellers (ATM)
• Entryways
• Roadside Emergency Sites
• Stairwells in Public Buildings
TECHNICAL
TECHNICAL
A
A
p
p
p
p
l
l
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
ADA Compliant Emergency Tower Phone
with Blue Strobe Light and Voice Announcer
E-1600A-BLT-EWP
E-1600A-BLT-EWP
E-1600A-BLT2-EWP
E-1600A-BLT2-EWP
ADA Compliant Emergency
Tower Phone with Strobe
March 7, 2008
• Enhanced Weather Protection (EWP)
• Meets ADA requirements for Emergency Phones:
- Can automatically light the “Call Connected” LED for the
hearing impaired
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired
• 16 second non-volatile digital voice announcer
• 1 million candle power blue strobe light
Advanced call progress detection
• Handsfree operation
• Phone line powered emergency phone (strobe requires power)
• Non-volatile memory (no batteries required)
• Touch Tone or pulse dialing
• Dials up to 5 emergency numbers
• Cycles through backup emergency and non-emergency
numbers on busy or no-answer
E-1600A-BLT2-EWP can also dial up to 3 non-emergency
“Info” numbers
• Hangs up on CPC, silence, busy signal, dial tone, time-out or
Touch Tone command
• Programmable to auto-answer on incoming calls
• Remotely programmable
• Extended temperature range (-15°F to 130°F)
• Central Station Monitoring capability (dials 2 numbers)
• Separate central station voice speed dial number
• Optional PB-100 Polling System available (see page 10)
• High visibility, vandal and weather resistant
• Vandal resistant polycarbonate strobe lens
• Surface mountable
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
P
P
h
h
o
o
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
8
8
6
6
1
1
CAUTION - When installing on an analog extension of a phone system: Some phone
systems do not conform to analog telecom standards and might not be compatible with the
1600A Series emergency phones. For a detailed description of the telephone line specifica-
tions required for any of the 1600A Series phones, retrieve Fax Back Document 869.
E-1600A-BLT-EWP E-1600A-BLT2-EWP