Whirlpool WFG110AV Specification Sheet

Download Specification sheet of Whirlpool  WFG110AVQ Cooktop for Free or View it Online on All-Guides.com. This version of Whirlpool  WFG110AVQ Manual compatible with such list of devices, as:  WFG110AVQ,  WFG111SVQ, WFG110AV, WFG110AVQ - 30" Standard Clean Gas Range, WFG111SV

Whirlpool  WFG110AVQ Specification sheet - Page 1
1
®
30" Freestanding Gas Range
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
SF110AXS WFG110AV
WFG111SV
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Gas supply: Use 3/4" rigid pipe gas supply line
to the range location. A smaller size pipe on long
runs may result in insufficient gas supply. With
L.P. gas, piping or tubing size can be 1/2"
minimum. If local codes permit, it is
recommended that new flexible metal tubing,
design-certified by CSA, 1/2-inch or 3/4-inch I.D.,
be used for connecting the range to the rigid gas
supply line. A 1/2" male pipe thread is needed for
connection to pressure regulator female pipe
threads. An individual manual shutoff valve must
be located in the same room, but external to the
range.
Electrical: A 120-volt, 60 Hz, AC-only, 15 amp,
electrical supply fused on both sides of the line. A
separate circuit is recommended. A time-delay
fuse or circuit breaker is recommended.
Ref. W10032070B
07-15-08
*** NOTE: 24" (61.0 cm) min. when bottom of wood or metal cabinet is
protected by not less than 1/4" (6.4 mm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm)
copper.
30" (76.2 cm) min. clearance between the top of the cooking
platform and the bottom of an unprotected wood or metal cabinet.
Contact a qualified floor covering
installer to check that the floor
covering can withstand at least 200°F.
Use an insulated pad or 1/4" (6.4 mm)
plywood under range if installing
range over carpeting.
For minimum clearance
to top of cooktop, see
NOTE.***
Do Not seal the range to
the side cabinets.
If cabinet depth is greater
than 24" (61.0 cm), oven
frame must extend
beyond cabinet fronts by
1/2" (1. 3 cm) min.
18" (45.7 cm) min.
clearance upper
side cabinet to
countertop
13" (33.0 cm)
max. upper
cabinet depth
30-1/8" (76.5 cm)
opening
width
30" (76.2 cm) min.
cabinet opening
width
8"
(20.3 cm)
2"
(5.1 cm)
10"
(25.4 cm)
24"
(61 cm)
5"
(12.7 cm)
5"
(12.7 cm)
3"
(7.6 cm)
2" (5.1 cm) min.
countertop space to
side wall or other
combustible material
This shaded area
recommended
for installation of
gas pipe.
This shaded area
recommended for
electrical outlet.
29-7/8" (75.9 cm)
width
46-1/4" (117.5 cm)
overall height for
tall backguard
models
24-1/4" (61.6 cm)
36"
(91.4 cm)
cooktop
height
26-3/4" (67.9 cm)
depth with handle