White Rodgers 1F83-71 User Manual

Download Installation and operation instructions manual of White Rodgers 1F83-71 Thermostat for Free or View it Online on All-Guides.com.

Brand: White Rodgers

Category: Thermostat

Type: Installation and operation instructions manual for White Rodgers 1F83-71

Pages: 6 (0.08 Mb)

Download White Rodgers 1F83-71 Installation and operation instructions manual

White Rodgers 1F83-71 Installation and operation instructions manual - Page 1
1
White Rodgers 1F83-71 Installation and operation instructions manual - Page 2
2
White Rodgers 1F83-71 Installation and operation instructions manual - Page 3
3
White Rodgers 1F83-71 Installation and operation instructions manual - Page 4
4
White Rodgers 1F83-71 Installation and operation instructions manual - Page 5
5
White Rodgers 1F83-71 Installation and operation instructions manual - Page 6
6
Printed in U.S.A.
DESCRIPTION
1F83-71
Non-Programmable Electronic
Digital Automatic Changeover Multi-stage Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
PART NO. 37-6126B
Replaces 37-6126A
0004
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
PRECAUTIONS
SPECIFICATIONS
CAUTION
!
WARNING
!
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
WHITE-RODGERS
Your new White-Rodgers Digital Multi-stage Thermostat uses
the technology of a solid-state microcomputer to provide precise
time/temperature control.
Features:
Simultaneous heat and cool setpoint storage
Optional C terminal (dual power option)
Optional B and O terminals
Preprogrammed temperature control
LCD continuously displays setpoint and room temperature
°F/°C convertibility
Temperature range 45° to 90°F
Two-stage heat/two-stage cool
Armchair programming capability
This thermostat is intended for use with a 24-volt system; do not
use this thermostat with a millivolt or line voltage system. If in
doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualified heating and air conditioning
contractor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment damage
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
ELECTRICAL DATA
Electrical Rating:
20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F
APPLICATIONS
For use with:
Heat/cool systems with up to two stages heat, two
stages cool
DO NOT USE WITH:
Millivolt systems
Systems exceeding 30 VAC and 2.5 amps
3-wire zoned hydronic heating systems