Tamarack Technologies HV1000 Product Manual

Download Product manual & installation manual of Tamarack Technologies HV1000 Fan, Network Router for Free or View it Online on All-Guides.com.

Tamarack Technologies HV1000 Product manual & installation manual - Page 1
1
Tamarack Technologies HV1000 Product manual & installation manual - Page 2
2
Tamarack Technologies HV1000 Product manual & installation manual - Page 3
3
Tamarack Technologies HV1000 Product manual & installation manual - Page 4
4
22
1/2”
12
HV1600
One (1) HV1600 Whole House Ventilator
One (1) White Metal Grille w/(6) Screws
Four (4) #8x3/4 Screws
One (1) Hand Held Remote Transmitter
HV1000
One (1) HV1000 Whole House Ventilator
One (1) White Metal Grille w/(6) Screws
One (1) Electrical Box Cover w/(2) Screws
Four (4) #8x3/4 Screws
One (1) Grounding Screw (green)
The serial number is located on the shipping carton
and on a label affixed to the upper housing.
When you have unpacked your HV carefully you will find the following:
READ AND SAVE THESE INSTRUCTIONS
Unpacking your HV:
Serial Number
Date of Purchase
Point of Purchase
The Best Location for your HV:
The HV should be installed in your attic in a central location within your home.
Above a central hallway or at the top of a stairwell will provide the best airflow. The fan can be mounted vertically.
Make sure that there aren’t any pipes, wires, rafters or air conditioning or heating ducts running through the space
where the HV will be installed and that the doors will open into an unoccupied area.
Make sure that you have adequate exhaust area out of your attic. This can be accomplished with a combination
of roof, ridge or gable end vents. The HV1000 requires a minimum of 3 square feet and the HV1600
requires 5 square feet of attic exhaust area.
Make sure that there is adequate clearance above the fan for the doors to open. The minimum requirement is 12”.
If your home has an engineered roofing system, care should be taken that the HV will fit within the truss layout.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being
switched on accidentally
. When the service disconnecting cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
Never place a switch where it can be reached from a tub or shower.
Do not use this fan over a tub or shower.
Do not use this fan over cooking appliances.
W
AR
NI
NG:
T
o
Re
d
u
c
e
The Ris
k
o
f Fir
e
or
Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
CAUTION: For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors
CAUTION: This unit has an unguarded impeller. Do Not Use in Locations Readily Accessible to People or Animals.
4”
6
3/4”
320 Main Street • Buzzards Bay, Ma 02532
508-759-4660 / 800-222-5932 / Fax 508-759-6001
WHOLE hoUSE
VENTILATORS
PRODUCT MANUAL & INSTALLATION GUIDE
HV Series
H
VM.07