Telex ALP-600 User Manual

Download Instruction manual of Telex ALP-600 Antenna for Free or View it Online on All-Guides.com.

Brand: Telex

Category: Antenna

Type: Instruction manual for Telex ALP-600

Pages: 4 (2.36 Mb)

Download Telex ALP-600 Instruction manual

Telex ALP-600 Instruction manual - Page 1
1
Telex ALP-600 Instruction manual - Page 2
2
Telex ALP-600 Instruction manual - Page 3
3
Telex ALP-600 Instruction manual - Page 4
4
IN STRUC TION MAN UAL
Gen eral De scrip tion
The ALP-600 is a broad band bi-directional log pe -
ri odic an tenna. It will re ceive any fre quency from
520 to 760 MHz. The “gain” of this an tenna en ables
it to re ceive sig nals from a greater dis tance than a
typ i cal “whip” type an tenna.
An tenna Place ment
The ALP-600 should be placed in a po si tion that
has a clear view of the trans mit ter(s) for best re -
sults. Ob struc tions such as walls, ceil ings, and
metal ob jects will re duce range and per for mance.
An tenna Mount ing
The ALP-600 is sup plied with hard ware for tu bu lar
clamp ing. It should al ways be mounted ver ti cally
with the ground and per pen dic u lar to the trans mit -
ter(s), See Fig ure 1.
Log Pe ri odic An tennas are also di rec tional and
will have the best re cep tion when pointed at the
trans mit ter. This yields the ben e fit of less in ter fer -
ence from un wanted sig nals com ing from the back
or side of the an tenna.
-1-
R
TELEXCOMMUNICATIONS,INC.
8601 East Cornhusker High way, P.O. Box 5579, Lin coln NE 68505
ALP-600
UHF Log Pe ri odic An tenna
Or der No. 878896 801542
SPEC I FI CA TIONS
(av er age)
Gain..................................................................................................................1.6 dBd
1/2 Power Beam Width .........................................................................................120°
Front-to-Back Ra tio...........................................................................................19.4 dB
SWR.......................................................................................................................1.5:1
In put Im ped ance ................................................................................................50 ohm
In put Con nec tor ....................................................................................................TNC
Size............................................................................12" (304.8mm) x 17" (431.8mm)
T
elex
TR-600
Fig ure 1