Totaline P707 Installation And Operation Instructions Manual

Download Installation and operation instructions manual of TOTALINE P707 Fan for Free or View it Online on All-Guides.com.

Brand: TOTALINE

Category: Fan

Type: Installation and operation instructions manual for TOTALINE P707

Pages: 16 (0.68 Mb)

Download TOTALINE P707 Installation and operation instructions manual

TOTALINE P707 Installation and operation instructions manual - Page 1
1
TOTALINE P707 Installation and operation instructions manual - Page 2
2
TOTALINE P707 Installation and operation instructions manual - Page 3
3
TOTALINE P707 Installation and operation instructions manual - Page 4
4
TOTALINE P707 Installation and operation instructions manual - Page 5
5
TOTALINE P707 Installation and operation instructions manual - Page 6
6
TOTALINE P707 Installation and operation instructions manual - Page 7
7
TOTALINE P707 Installation and operation instructions manual - Page 8
8
TOTALINE P707 Installation and operation instructions manual - Page 9
9
TOTALINE P707 Installation and operation instructions manual - Page 10
10
TOTALINE P707 Installation and operation instructions manual - Page 11
11
TOTALINE P707 Installation and operation instructions manual - Page 12
12
TOTALINE P707 Installation and operation instructions manual - Page 13
13
TOTALINE P707 Installation and operation instructions manual - Page 14
14
TOTALINE P707 Installation and operation instructions manual - Page 15
15
TOTALINE P707 Installation and operation instructions manual - Page 16
16
Manufacturer reserves the right to
discontinue, or change at any time,
specifications or designs without notice
and without incurring obligations.
REPLACEMENT COMPONENTS DIVISION LITERATURE NUMBER P707-5SI
© CARRIER CORPORATION 2004 4-04 REPLACES: New
PRINTED IN U.S.A. CATALOG NUMBER 570-332
Part Numbers P707-SHR1504 and 2004
CONTENTS
SAFETY CONSIDERATIONS ...................... 1
GENERAL ........................................1
INSTALLATION ................................ 2-10
Step 1 — Unit Location...........................2
Step 2 — Unit Mounting .......................... 2
Step 3 — Install Drain Line .......................3
Step 4 — Locate and Install Weather Hoods......3
Step 5 — Install Ducting To Weather Hood
Location .......................................3
Step 6 — Install Indoor Ductwork System ........4
SUPPLY AIR DUCTING
EXHAUST AIR DUCTING
INSTALL DUCTING
INSTALLATION EXAMPLES
Step 7 — Airflow Balancing ......................6
AIRFLOW STATION METHOD
PITOT TUBE BALANCING PROCEDURE
BALANCING DAMPER ADJUSTMENT
Step 8 — Install Accessories .....................9
Step 9 — Electrical Connection to Furnace
(Air Systems Directly Connected to Furnace) ..9
OPERATION...................................10,11
Winter...........................................10
Spring...........................................10
Summer.........................................10
Fall ..............................................10
Modes of Operation .............................10
CONTINUOUS/VENTILATION MODE
INTERMITTENT/STANDBY MODE
DEFROST (FAN SHUTDOWN)
MAINTENANCE ................................. 11
Motor ........................................... 11
Chassis .........................................11
Condensation Panel............................. 11
Drain and Drain Line ............................ 11
Outside Hoods .................................. 11
Filters ........................................... 11
Heat Recovery Core ............................. 11
TROUBLESHOOTING............................12
SAFETY CONSIDERATIONS
Installing, starting up, and servicing ventilation equipment
can be hazardous due to system pressures, electrical compo-
nents and equipment location (roofs, elevated structures, etc.).
Only trained, qualified installers and service mechanics should
install, start up, and service this equipment.
When working on the equipment, observe precautions in the
literature and on tags, stickers, and labels attached to the
equipment. Follow all safety codes.
GENERAL
The P707-SHR1504 and P707-SHR2004 Heat Recovery
Ventilators (HRV) are used to exchange indoor stale air with
outside fresh air. The HRV unit is equipped with a special ener-
gy recovery core which transfers sensible heat with the fresh
incoming air. The cross-flow design core allows entering and
leaving airstreams to transfer heat energy without mixing.
The HRV is available in 2 sizes with airflow ranges of
150 cfm (SHR1504), and 200 cfm (SHR2004). The design of
this unit is horizontal. Special attention should be given to duct
application, balancing the HRV, and locating unit for easy
access and routine maintenance. See Table 1 and Fig. 1 for
performance data.
Table 1 — Performance Data
Before installation, always check to be sure main power to
systems are OFF. Electrical shock can cause personal
injury or death.
UNIT
APPARENT SENSIBLE
EFFECTIVENESS
AT 32 F (0° C)
APPARENT SENSIBLE
EFFECTIVENESS
AT –13 F (–24 C)
SHR 1504 72% 69%
SHR 2004 71% 76%
INSTALLATION
AND OPERATION
INSTRUCTIONS
P707
Heat Recovery
Ventilator
0
0.2
0.4
0.6
0.8
1
1.2
0
50
100
150
200
250
300
40080
SHR 1504
SHR 2004
120 160
AIRFLOW (CFM)
AIRFLOW (L/S)
STATIC PRESSURE (IN. WG)
STATIC PRESSURE (PA)
200 240
190 38 57 76 94 114
Fig. 1 — Fan Performance