Follett U155B Installation, Operation & Service Manual

Download Installation, operation & service manual of Follett U155B Beverage Dispenser for Free or View it Online on All-Guides.com. This version of Follett U155B Manual compatible with such list of devices, as: U155B, U155BR400A/W, U155BXR400A/W, U155X, U155XR400A/W

Follett U155B Installation, operation & service manual - Page 1
1
Follett U155B Installation, operation & service manual - Page 2
2
Follett U155B Installation, operation & service manual - Page 3
3
Follett U155B Installation, operation & service manual - Page 4
4
Follett U155B Installation, operation & service manual - Page 5
5
Follett U155B Installation, operation & service manual - Page 6
6
Follett U155B Installation, operation & service manual - Page 7
7
Follett U155B Installation, operation & service manual - Page 8
8
Follett U155B Installation, operation & service manual - Page 9
9
Follett U155B Installation, operation & service manual - Page 10
10
Follett U155B Installation, operation & service manual - Page 11
11
Follett U155B Installation, operation & service manual - Page 12
12
Follett U155B Installation, operation & service manual - Page 13
13
Follett U155B Installation, operation & service manual - Page 14
14
Follett U155B Installation, operation & service manual - Page 15
15
Follett U155B Installation, operation & service manual - Page 16
16
Follett U155B Installation, operation & service manual - Page 17
17
Follett U155B Installation, operation & service manual - Page 18
18
Follett U155B Installation, operation & service manual - Page 19
19
Follett U155B Installation, operation & service manual - Page 20
20
Follett U155B Installation, operation & service manual - Page 21
21
Follett U155B Installation, operation & service manual - Page 22
22
Follett U155B Installation, operation & service manual - Page 23
23
Follett U155B Installation, operation & service manual - Page 24
24
16
Condition Pump Solenoids Auger Wheel Beverage
valves
Top lid off OFF ON OFF OFF ON
Rear lid off ON ON OFF OFF ON
Drain pan off ON ON OFF OFF OFF
On/off switch
in off position OFF OFF OFF OFF OFF
Beverage
switch in OFF
position ON ON ON ON OFF
Operational Status
The chart below shows the operational status of various parts when certain switches are turned off or accessories
are removed.
Electrical box
Front View
Waterbath circuit board operation
The temperature sensor is hard wired directly to the circuit board. The waterbath circuit board operates on 24
volts AC. The bath pump will run for 35 minutes whenever ice is dispensed or the bath calls for ice.
Optimal beverage temperature is controlled by the circuit board located in the electrical box. The board monitors
the waterbath temperature and holds it to a factory setting. When the Red
LED is ON, the bath solenoid, auger
motor, wheel motor and bath pump are energized. Ice will be dispensed into the waterbath for 12 seconds, then
stop for 60 seconds. The pump will stay energized, and the circuit board will then monitor the water
temperature. If it is below the set point, the Green
LED will come on, the Red LED light will go off, and ice will
not dispense into the waterbath. If the temperature of the bath is determined to be above the set point, the Red
LED will remain on. The circuit board has a delay of 60 seconds before more ice is dispensed into the
waterbath.
LED indicators:
Green
– the waterbath is at the set temperature.
Red – the bath temperature is above the set temperature and the bath is calling for ice.
Flashing LED indicators:
Flashing Red and Green
– the circuit board has gone into an error mode:
Alternate flashing – circuit board has power and is waiting for hopper cover and dispenser top to be
replaced.
Simultaneous flashing
– the waterbath did not reach set temperature in 40 minutes. Reset this error
mode by turning power off, removing top lid, drain pan or rear lid.
I
0
I
0
I
0
power on/off
switch
#1 #2
icemaker
switches
probe
warm/red LED
cold/green LED
bev. bath
indicator