Foster F20 User Manual

Download Service manual of Foster F20 Ice Maker for Free or View it Online on All-Guides.com. This version of Foster F20 Manual compatible with such list of devices, as: F20, F40, F85, FCI20, FCI40

Foster F20 Service manual - Page 1
1
Foster F20 Service manual - Page 2
2
Foster F20 Service manual - Page 3
3
Foster F20 Service manual - Page 4
4
Foster F20 Service manual - Page 5
5
Foster F20 Service manual - Page 6
6
Foster F20 Service manual - Page 7
7
Foster F20 Service manual - Page 8
8
Foster F20 Service manual - Page 9
9
Foster F20 Service manual - Page 10
10
Foster F20 Service manual - Page 11
11
Foster F20 Service manual - Page 12
12
Foster F20 Service manual - Page 13
13
Foster F20 Service manual - Page 14
14
Foster F20 Service manual - Page 15
15
Foster F20 Service manual - Page 16
16
Foster F20 Service manual - Page 17
17
Foster F20 Service manual - Page 18
18
Foster F20 Service manual - Page 19
19
Foster F20 Service manual - Page 20
20
Foster F20 Service manual - Page 21
21
Foster F20 Service manual - Page 22
22
Foster F20 Service manual - Page 23
23
F20 & F40 A/W Wiring Diagram
7
the service and inspection operations.
IN OPERATION:
The unit is running through the freezing and defrost cycle stopping automatically only at full bin situation.
RE-SET/HI TEMPERATURE: To be selected to resume the unit operation when the ice maker shuts off due to the intervention of the condenser
temperature sensor (too high condensing temperature).
The five LEDS, placed in a row in the front of the P.C. BOARD, monitor the following situations:
GREEN LIGHT: Unit under electrical power
YELLOW LIGHT: Unit shut-off at full storage bin
RED LIGHT: Unit shut-off due to hi-condensing
temperature
Blinking: Unit shut-off due to hi-evaporating
temperature
YELLOW LIGHT:
Unit in freezing operation
YELLOW LIGHT: Unit in cleaning/rinsing mode
12.6 DIP SWITCH
The P.C. BOARD which controls the entire operation of the ice maker, has a DIP SWITCH with ten switching keys which allow to set up the
micro processor program in order to extend or to shorten the length of freezing and defrost cycles in relation to the different models and versions
of ice machines.
The DIP SWITCH first four keys setting determines the length of the 2nd phase of freezing cycle (controlled by the electronic timer) as detailed
in Table B.
The DIP SWITCH keys 5, 6 and 7 setting determines the length of the defrost cycle according to the ambient temperature sensor as specified
in table C.
The 8th DIP SWITCH key allows to make a rapid check up of the P.C. BOARD output connections (compressor, water pump, fan motor, water
inlet and hot gas solenoid valves) energizing them in rapid sequence (2 seconds) one by one.
DURING THE AUTOMATIC OPERATION OF THE ICE MAKER THIS KEY MUST BE SET IN OFF POSITION.
ATTENTION: The check up of the P.C. BOARD output must be performed in a very short time in order to avoid frequent starts and stops (every
few seconds) of the electrical components which may damage them, especially the compressor.
The 9th key
allows the operation of the water pump even during the defrost cycle. On B 90 it must be set all the time to OFF position.
The 10th key is used to supply power to the water pump during the first 15-20 seconds of the defrost cycle to drain out all remaining water from
the sump tank in the unit equipped with the solenoid drain valve i.e. the KWD drain system.
13. Dip Switch Settings FCI 40-60-85
Dip switch 1 2 3 4 5 6 7 8 9 10
FCI 40 ON ON OFF ON ON ON OFF OFF ON OFF
FCI 40 W ON ON OFF ON ON ON OFF OFF ON OFF
FCI 60 ON ON OFF ON ON ON OFF OFF ON OFF
FCI 60 W ON ON OFF ON ON ON OFF OFF ON OFF
FCI 85 OFF OFF ON ON ON ON OFF OFF ON OFF
FCI 85 W OFF OFF ON ON ON ON OFF OFF ON OFF
Table B
Table C
Table A
18
LENGTH OF TIMED PORTION OF FREEZING CYCLE ACCORDING TO DIP SWITH COMBINATIONS
1 2 3 4 1 2 3 4
1 ON ON OFF OFF 25 min 8 OFF ON OFF ON 11 min
2 OFF OFF ON OFF 23 min 9 ON ON OFF ON 9 min
3 ON OFF ON OFF 21 min 10 OFF OFF ON ON 7min
4 OFF ON ON OFF 19 min 11 ON OFF ON ON 5 min
5 ON ON ON OFF 17 min 12 OFF ON ON ON 3 min
6 OFF OFF OFF ON 15 min 13 ON ON ON ON 1 min
7 ON OFF OFF ON 13 min
LENGTH OF DEFROST CYCLE (IN SEC.) ACCORDING TO THE AMBIENT TEMPERATURE AND TO
DIP SWITCH SETTING COMBINATIONS
5 6 7 0-5°C 5-10°C 10-15°C 15-20°C 20-25°C 25-30°C 30-35°C 35-40°C
ON ON OFF 180 sec 150 sec 120 sec 90 sec 90 sec 90 sec 90 sec 90 sec
OFF OFF ON 210 sec 180 sec 150 sec 120 sec 120 sec 120 sec 90 sec 90sec
ON OFF ON 240 sec 210 sec 180 sec 150 sec 150 sec 120 sec 120 sec 90 sec
OFF ON ON 240 sec 210 sec 180 sec 150 sec 150 sec 120 sec 120 sec 120 sec
ON ON ON 270 sec 240 sec 210 sec 180 sec 180 sec 150 sec 150 sec 150 sec