3-Phase Switched PDU, 8.6 kW, 24 208V outlets
(21-C13, 3-C19) 10-ft. Cord, NEMA L15-30P 30A
input, 0U vertical mount
MODEL NUMBER: PDU3VSR10L1530
Description
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with
the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical
conditions and remotely monitor output power consumption per-phase or per-receptacle. PowerAlert interface
supports remote control and custom notification of user-specified conditions via email, secure web, SNMP,
Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot
unresponsive network hardware, or be custom programmed for user-defined power-up and power-down
sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as
network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the
connection of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can
be displayed locally via visual meter or remotely via web/network interface to warn of potential overloads before
critical IT mains or branch breakers trip.
Features
8.6kW 3 phase 208V Switched Power Distribution Unit / PDU with built-in web/network interface
Attached NEMA L15-30P 30A (3P+E) 208V 3 phase input; 10 ft. / 3m cord
0U, 70 inch / 178cm vertical form factor
24 switched 208V outlets (21 C13, 3 C19) in 3 single phase load banks
Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
Network interface provides PDU control and data regarding input voltage, per-outlet and per-phase load levels
Digital display with scroll-buttons supports per-outlet or per-phase load levels, IP-address self-identification and 180 degree display rotation
Supports user-specified alarm notification thresholds
In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH
door sensors
Highlights
Switched 8.6kW 3 Phase 208V
PDU; 70 in. / 178cm 0U vertical
rackmount
Reports voltage, frequency &
load per-outlet or phase via
ethernet interface
Visual current meter; Toolless
button-mount installation
NEMA L15-30P 30A (3P+E) 208V
3 phase input; 10 ft. / 3m line
cord
21 C13 & 3 C19 single phase
switched outlets with cord
retention brackets
Temperature, humidity and
contact closure monitoring options
Applications
Ideal for 3 phase network
configurations in datacenters and
heavily configured equipment
racks
Package Includes
Switched rackmount PDU with
pre-installed mounting buttons
Plug retention plates
Spare installation buttons (2
9mm / 4 6mm)
Rack mounting brackets
Owner's manual
1 / 4