Fujioh EBW-600 Instalation Manual

Download Instalation manual of Fujioh EBW-600 Ventilation Hood for Free or View it Online on All-Guides.com.

Brand: Fujioh

Category: Ventilation Hood

Type: Instalation manual

Model: Fujioh EBW-600 , Fujioh EBW-660

Pages: 2 (1.07 Mb)

Download Fujioh EBW-600 Instalation manual

Fujioh EBW-600 Instalation manual - Page 1
1
Fujioh EBW-600 Instalation manual - Page 2
2
1
The range hood must be installed just
above the cooktop.
2
The minimum distance from the cooking
surface to the bottom of the range hood
must be 24".
3
The total weight of the range hood units
are as follows;
4
Power requirements are:
AC120 V, 60 Hz, 2.7 Amp
INSTALLATION MANUAL
Model: EBW-600/660
1U03 2581
Before installation and operation, read these instructions carefully
and use this product only in the manner described by the
manufacturer in the operation manual.
The instruction shown below are used to alert you to potential
personal injury and property damage hazards.
There are three hazard classifications based on potentially
dangerous situations.
Obey all safety instructions that show these symbols to avoid
possible injury, death and property damage.
SAFETY INSTRUCTIONS
WARNING:
WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION:
CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
NOTE: The safety instructions are explained with the following
pictographic symbols.
means forcible execution. It indicates actions, if
any, that must be done.
WARNING
1. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning the unit, switch power
off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
CAUTION
INSTALLATION
1. Preparation
2
Remove one
screw fixing the
wire cover and
detach it.
5. Function Check
Range Hood
3. Read specification label on this product for further
information and requirements.
2. To reduce the risk of fire and to properly exhaust
air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls, ceilings or into attics,
crawl spaces or garages.
6. Fasten the filter and other parts securely. Incorrect
attachment may result in personal injury or
property damage.
4. Use only for the purpose of kitchen ventilation.
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and
vapors.
5. Do not install this range hood in the bathroom or
in other wet rooms since electrical shock and
damage may result.
2. To reduce the risk of fire or electric shock, do not
use this product with any solid-state speed control
device.
b) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and The American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
d) Ducted fan must always be vented to outdoors.
1
This range hood is designed to discharge upward or
backward. For vertical or horizontal discharge, run
duct work between the hood location and roof cap or
wall cap location.
To get the best result, use a minimum number of
transitions and elbows.
Be sure to attach a roof cap or wall cap to avoid
rain from entering into the exhaust duct.
2
Arrange the ends of 7" round duct and wiring conduit
so that they can connect with the top of the range
hood unit.
Ensure that the metal duct does not touch other metal
housing materials, otherwise fire or electric shock could
result.
Install the range hood unit on a
wall strong enough to support its
weight. Otherwise, it may
become detached and fall down.
6. Explanation to the End User
(1) Referring to the Operation Manual, explain the
operation of this range hood to the end user.
(2) The Installation Manual and Operation Manual should
be given to the end user.
(1) Turn on the power to the range hood.
(2) Make sure that the switches and light operate
correctly.
Refer to page 4 of the Operation Manual.
(3) Make sure that the range hood functions properly
and it has no abnormal noises and/or vibration.
Be sure to switch OFF the power at service panel
before wiring.
3
Connect the conduit through the connecting hole of
the enclosure using the nut previously removed.
CAUTION:
CAUTION used without the safety
alert symbol indicates a potentially
hazardous situation which, if not
avoided, may result in property
damage.
means prohibition. It indicates actions, if any,
that mustn’t be done.
4. TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
5. This unit must be grounded.
6. Check that the hood is correctly installed, since
incorrect installation could result in the range hood
becoming detached and falling off.
7. Connect only to an AC120 Volt power source or
the range hood could result in fire, electric shock,
and damage.
CIRCUIT DIAGRAM
CAUTION:
WARNING:
WARNING:
3
Tighten both the left and right screws, then put 2
supplied screws (M5.1×45) in the holes under the
keyholes and tighten them firmly.
NAMES OF PARTS
RANGE HOOD LOCATION
Check that the hood is correctly installed, since incorrect installation could
result in the detachment of the range hood and the unit could fall down.
To protect hands from injury, wear working gloves when installing the range
hood.
CAUTION:
ACCESSORIES
Screw M5.1×45 ........ Four (4) pcs.
Screw M4×10 ........... Two (2) pcs.
3
Referring to “DIMENSIONS” above, insert 2 supplied
screws (M5.1×45) into the mounting wall for the left
and right keyholes of the cabinet. Allow about 5mm
space between the wall and screw-heads for hanging.
4
Make the duct joint secure and air-tight using non-
flammable tape (not supplied).
3. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction.
• Black to Black
• White to White
• Green to Green
4. Attaching Front Cover and
Front Panel
2
With holding the front panel by both hands, engage
the upper hook of the front panel.
EBW-600 46.3 lbs. (21.0kg)
EBW-660 50.7 lbs. (23.0kg)
*without front panel
DIMENSIONS
Unit: inch (mm)
4
Fix the front panel using 2
screws (M4×10) supplied.
4
Connect wires tightly and securely using wire
connectors (not supplied).
Connect the electrical wires as follows:
Note: Be sure to reinforce the wall with some wood
panel.
5
Attach 2 cover plates (supplied with the front panel) to
the left and right of the front panel as illustrated.
(1) Hook the cover plate on the front panel.
(2) Press the cover plate until it is locked.
5
Replace the wire
cover with the
screw removed
previously. Make
sure that all wires
are connected
properly and
enclosed inside of
the wiring
compartment.
Front panel
Front cover
Slot Filter
Exhaust port
Enclosure
Switch
Lamp (MR16, GU10, 35Watt)
(Not supplied)
120V
60Hz
Connector
Connector
Connector
Connector
Connector
Connector
Motor
Red
Orange
Orange
White
White
White
White
White
White
White
Black
Green
Blue
Blue
Brown
Brown
Black
Black
Black
Black
Black
Black
White
Black
Black
Grey
Yellow
Black
Black
Pilot Lamp
Lamp
Lamp
Fan SwitchLamp Switch
Capacitor
Cook top
24"(minimum)
Range hood
Soffit
Roof cap
7" round duct
(For vertical discharge)
Wall cap
Duct
Range hood unit
1-3/16"
(30)
EBW-660:18"(457)
EBW-600:15"(381)
6"(150)
7"(176)
3/16"(5)
Wall
Wood panel
Wall stud
Wood panel
Wall
Cover plate
Lock
Hook
Front panel
Cover plate
2
1
Lamp (MR16, GU10, 35W)
(Not supplied)
Push the lamp, and
turn it clockwise.
Wire cover
Wires
(conduit side)
Wires (unit side)
Wire connector
(not supplied)
Conduit
Wire box
Nut
Wire cover
Non-flamable tape
Tighten
3
Lower the bottom of the front panel slowly with
checking that the front panel has hung on the left and
right stoppers of the enclosure, then insert both the left
and right tabs of the front panel into the slits of the
enclosure.
Note: Be careful not to drop the front panel to avoid
injury.
Front panel
Stopper
3
3
2
2
3
2. Range Hood Mounting
CAUTION:
Wear working gloves to avoid injury.
2
With inserting the exhaust port to the duct, hook
both the left and right keyholes of the enclosure on
the screws provided “1. Preparation” in step 3.
Wood panel
7" round duct
How to remove the cover plate
While holding the cover plate, slide a flat-head
screwdriver into the gap below.
6
Install two light bulbs.
Two 35 W halogen light bulbs (not supplied) can be
mounted to this range hood.
Prior to function check, install light bulbs (Bulb type
MR16, GU10), rated 120 V-35 W or below.
Note: When installing the bulb, be sure to fix to the
socket securely.
Push to turn ON
7. Keep your hands and other objects away from
the fan while it is in motion. The range hood may
injure you or damage itself.
Exhaust port
Cover Plate
3. Connecting Power
Supply Wires
1
Remove the nut (not
supplied) from the conduit
connector at the end of
power wiring.
Electrical wiring should be done by a qualified
person(s) in accordance with all applicable codes
and standards, including fire-rated construction. An
unqualified person doing the work could result in fire,
electric shock or injury.
This range hood uses 120V AC. Do not connect to
other voltage since fire, electric shock or damage
could result.
WARNING:
Conduit
(Not supplied)
Nut
(Not supplied)
Cord clamp
Loosen
6P connector
U-cut
Pull up
Wood panel
Tighten
Non-flammable
tape
Range hood
Duct
U-cut
U-cut
Cord clamp
Tighten
6P connector
Note: This range hood can directry connect to the
duct without using the supplied exhaust port.
Refer to the steps desclibed under “In case
of direct duct connection” in 2. Range Hood
Mounting.
1
Attach the supplied exhaust port on the top of the
range hood with 4 screws.
In case of using exhaust port
In case of direct duct connection
1
Remove 3 screws and loosen 2 screws.Make the
wire free from cord clamp, then disconnect 6P
connector.
Place the range hood on the floor
2
Pull up the top of the fan unit and detach it with
disengaging its bottom U-cut part.
3
With inserting the duct into the top of the range
hood,hang its keyholes on the screws
provided“1.Preparation” in step 3.
5
Make the duct joint secure and air-tight from inside
using non-flammable tape (not supplied).
4
Tighten both the left and right screws, then put 2
supplied screws (M5.1×45) in the holes under the
keyholes and tighten them firmly.
6
Engage the bottom U-cut part of the fan unit with
loosened screws.
7
Fix the fan unit using removed 3 screws and
tightening 2 screws.
Connect 6P connector and fix the wire with the cord
clamp.
A
B
10-5/16"(262)
17-11/16" (450)
AB
EBW-600
30"(762)
36"(914)
EBW-660
29-1/2"(750)
23-5/8"(600)
C
30"(762)
24"(610)
30"(762)
24"(610)
R3/16"(R4)
5-15/16"(150)
6-1/2"(165)
12-15/16"(328)
C
9-13/16"
(250)
18-7/8"(480)
2-9/16"(65)
23-1/2"(597)
6-1/2"
(165)
10-1/2"(266)
6-15/16"
(
176)
7/8"(22.6)
11/16"(
18)
TOP VIEW
FRONT VIEW
BOTTOM VIEW
RIGHT SIDE VIEW
11-15/16"(304)
4
Remove 4 screws.
Front cover
Pull up
5
Detach the front
cover with pulling
up its bottom side.
Note:
Please be careful
not to damage
the cover plate by
the flat-head
screwdriver.
Front cover
Enclosure
Front cover
1
Insert the upper side of the front cover into the
enclosure as shown, and fix it using 4 screws.