GE JKP30 Install Manual

Download Installation instructions of GE JKP75SPSS Convection Oven, Kitchen Appliances for Free or View it Online on All-Guides.com. This version of GE JKP75SPSS Manual compatible with such list of devices, as: Profile PT970, JKP30SPSS, JTP30BMBB, JTP55DPBB, Profile PT956SMSS

Brand: GE

Category: Convection Oven , Kitchen Appliances , Microwave Oven , Oven

Type: Installation instructions

Model: GE JKP75SPSS , GE JTP70SMSS , GE JTP70SPSS , GE JTP75BM , GE JTP75SPSS , GE PK916 , GE PK956 , GE Profile PT916SMSS , GE Profile PT956 , GE Profile PT960DP , GE Profile PT970 , GE PT920 , GE PT960 , GE PT960SPSS , GE JKP90 , GE JKP90BMBB - 27-in Double Microwave/Thermal Wall Oven , GE JKP90SMSS , GE CT918STSS , GE CT959STSS , GE JKP30 , GE JKP30DP , GE JKP30DPBB , GE JKP30DPCC , GE JKP30DPWW , GE JKP30SMSS , GE JKP30SPSS , GE JKP30WMWW , GE JKP35DP , GE JKP35DPBB , GE JKP35DPWW , GE JKP35SMSS , GE JKP35SPSS , GE JKP55DP , GE JKP55DPBB , GE JKP55DPCC , GE JKP55DPWW , GE JKP55SMSS , GE JKP55SPSS , GE JKP55WMWW , GE JKP70 , GE JKP70DP , GE JKP70DPBB , GE JKP70DPWW , GE JKP70SMSS , GE JKP70SPSS , GE JKP70WMWW , GE JKP75BM , GE JKP75BMBB , GE JKP75DPBB , GE JKP75DPWW , GE JKP75SMSS , GE JKP90DP , GE JKP90DPBB , GE JKP90DPBB - 27 in. Double Microwave/Thermal Wall Oven , GE JKP90DPWW , GE JKP90DPWW - 27 in. Double Microwave/Thermal Wall Oven , GE JKP90SPSS , GE JKP90SPSS - 27" Combo Electric Oven , GE JKP90WMWW - 27 Inch Combination Wall Oven , GE JKS10DPBB , GE JKS10SPSS , GE JT930SKSS , GE JT980SKSS , GE JTP30 , GE JTP30BMBB , GE JTP30DP , GE JTP30DPBB , GE JTP30DPCC , GE JTP30DPWW , GE JTP30SMSS , GE JTP30SPSS , GE JTP30WMWW , GE JTP31SRSS , GE JTP35BMBB , GE JTP35DP , GE JTP35DPBB , GE JTP35DPWW , GE JTP35SMSS , GE JTP35SMSS - 30" Double Electric Wall Oven , GE JTP35SPSS , GE JTP35WMWW , GE JTP55 , GE JTP55DP , GE JTP55DPBB , GE JTP55DPWW , GE JTP55SMSS - 30 Inch Double Electric Wall Oven , GE JTP55SPSS , GE JTP55WMWW , GE JTP70BMBB , GE JTP70DP , GE JTP70DPBB , GE JTP70DPBB - 30" - Single Convection Electric Wall Oven , GE JTP70DPWW , GE JTP70WMWW , GE JTP75DP , GE JTP75DPBB , GE JTP75DPWW , GE JTP90BMBB , GE JTP90DP , GE JTP90DPBB , GE JTP90DPBB - 30" Combination Wall Oven , GE JTP90DPCC , GE JTP90DPWW , GE JTP90DPWW - 30" Combination Wall Oven , GE JTP90SPSS , GE JTS10DP , GE JTS10DPBB , GE JTS10SPSS , GE PK916BMBB - 27 Inch Single Electric Wall Oven , GE PK916DRBB , GE PK916DRCC , GE PK916DRWW , GE PK916SMSS - Profile 27 in. Wall Oven , GE PK916SRSS , GE PK916WMWW - 27 Inch Single Electric Wall Oven , GE PK956BMBB - 27 Inch Double Electric Wall Oven , GE PK956DRBB , GE PK956DRCC , GE PK956DRWW , GE PK956SMSS , GE PK956SRSS , GE PK956WMWW , GE Profile PK916SMSS , GE Profile PT920DP , GE Profile PT920SPSS , GE Profile PT956SMSS , GE PT900DRBB , GE PT900SRSS , GE PT916BMBB - 30 Inch Single Electric Wall Oven , GE PT916CMCC - 30 Inch Single Electric Wall Oven , GE PT916DRBB , GE PT916DRCC , GE PT916DRWW , GE PT916SMSS - 30 Inch Single Electric Wall Oven , GE PT916SRSS , GE PT916WMWW - 30 Inch Single Electric Wall Oven , GE PT920DRBB , GE PT920SRSS , GE PT956DRBB , GE PT956DRCC , GE PT956DRWW , GE PT956SMSS - 30 Inch Double Electric Wall Oven , GE PT956SRSS , GE PT956WMWW - 30 Inch Double Electric Wall Oven , GE PT958DRBB , GE PT958SRSS , GE PT960BMBB , GE PT960DRBB , GE PT960SMSS - 30 Inch Double Electric Wall Oven , GE PT960SRSS , GE PT970DRBB , GE PT970DRWW , GE PT970SRSS

Pages: 4 (2.55 Mb)

Download GE JKP75SPSS Installation instructions

GE JKP75SPSS Installation instructions - Page 1
1
GE JKP75SPSS Installation instructions - Page 2
2
GE JKP75SPSS Installation instructions - Page 3
3
GE JKP75SPSS Installation instructions - Page 4
4
CUTOUT FOR SINGLE OVENS IN WALL CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick,
shim both sides equally to establish the cutout width.
A2
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with Consumer.
Note to Consumer – Keep these
instructions for future reference.
Skill level – Installation of this appliance
requires a qualified installer or electrician.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under Warranty.
Installation Instructions
27" & 30" Electric Built-In Wall Ovens
31-10730-1
08-09 JR
FOR YOUR SAFETY:
WARNING
:
Before beginning the installation, switch power off at the service
panel and lock the service disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure.
Weight on the oven door could cause the oven to tip and result in injury. Never allow anyone to climb,
sit, stand or hang on the oven door.
Make sure the wall coverings, counters and cabinets around the oven can withstand the heat
(up to 200°F [93.3°C]) generated by the oven.
Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
MATERIALS YOU MAY NEED
Junction Box
Wire Nuts
Strain Relief Clamp for 1/2" Conduit
36" (91 cm) of String
TOOLS YOU MAY NEED
1/8" Drill Bit and Electric or Hand Drill
Phillips Screwdriver
Wire Strippers
REMOVE PACKAGING MATERIALS
Failure to remove packaging materials could result in damage to the appliance. Remove all
packing parts from oven, racks and heating elements. Remove protective film and labels on the
outer door and control panel. Also, remove plastic on trims and panel, all tape around the oven
and any shipping screws securing the oven to the base pad. Open oven door and remove
literature pack and oven racks. Remove the bottom trim from the top of the oven. It will be
installed at the end of the installation process. The trim is wrapped separately and taped
to the top of the unit.
1
PREPARE THE OPENING (FOR INDOOR USE ONLY)
NOTE: If the cabinet does not have a solid bottom,
two braces or runners must be installed to support
the weight of the oven. For single ovens, the runners
and braces must support 200 lbs (91 kg). For double
ovens, the runners and braces must support 375 lbs.
(170 kg).
NOTE: If marks, blemishes or the cutout opening are
visible above the installed oven, it may be necessary
to add wood shims under the runners and front trim
until the marks or opening are covered.
NOTE: If the cabinet does not have a front frame
and the sides are less than ¾" (1.9 cm) thick, shim
both sides equally to establish the cutout width.
2
ATTENTION INSTALLER: All electric wall ovens must be hard-wired (direct-wired)
into an approved junction box. A plug and receptacle is NOT permitted on these products.
These ovens are not
approved for stackable
installations.
Cutout –
observe all
dimensions and
requirements.
Cutout –
observe all
dimensions and
requirements.
2" (5.1 cm) Min.
30.5" (77.5 cm)
Center Line Center Line
Side-by-Side Installations (30" only)
Install two ovens in separate cutouts.
Dimension Dimension Description 27" Single Oven 30" Single Oven
A Cabinet Width 27" (68.6 cm) 30" (76.2 cm)
B Cutout Width 25" (63.5 cm) min. 28
1
2" (72.4 cm) min.
25
1
4" (64.1 cm) max. 28
5
8" (72.7 cm) max.
C Cutout Height 27
5
8" (70.2 cm) min. 27
1
4" (69.2 cm) min.
28
1
8" (71.4 cm) max. 27
5
16" (69.4 cm) max.
D Overlap of Oven Over 1" (2.5 cm)
11
16" (1.75 cm)
Side Edges of Cutout
E Clearance to 20" (50.8 cm) min. 21" (53.3 cm) min.
Adjacent Corners,
Drawers, Walls, etc.,
When Door Is Open
F Overlap of Oven 1" (2.5 cm) min. 1" (2.5 cm) min.
Top of Cutout
G Overlap of Oven 1" (2.5 cm) min. 1
1
4" (3.2 cm)
Bottom of Cutout
H Junction Box Location 8
3
4" (22.2 cm) max. 9
1
2" (24.1 cm) max.
right side only right side only
CUTOUT FOR DOUBLE OVENS
(with Upper Microwave Oven)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾" (1.9 cm) thick,
shim both sides equally to establish the cutout width.
D2
Dimension 27" Oven 30" Oven
Dimension Description with Microwave with Microwave
A Cabinet Width 27" (68.6 cm) 30" (76.2 cm)
B Cutout Width 25" (63.5 cm) min. 28
1
2" (72.4 cm) min.
25
1
4" (64.1 cm) max. 28
5
8" (72.7 cm) max.
C Cutout Height 41
1
8" (104.5 cm) min. 42
3
16" (107.2 cm) min.
41
1
4" (104.8 cm) max. 42
1
4" (107.3 cm) max.
D Overlap of Oven 1" (2.5 cm)
11
16" (1.75 cm)
Over Side Edges
of Cutout
E Clearance to Adjacent 20" (50.8 cm) min. 21" (53.3 cm)
Corners, Drawers, Walls,
etc., When Door Is Open
F Overlap of Oven 1" (2.5 cm) min. 1" (2.5 cm) min.
Top of Cutout
G Overlap of Oven 1" (2.5 cm) min. 1
1
4" (3.2 cm)
Bottom of Cutout
H Junction Box Location 8
3
4" (22.2 cm) max. 9
1
2" (24.1 cm) max.
right side only right side only
Continue to Section 3.
Suitable
Bracing
to Support
Runners
C
L
21 5/8"
(54.9 cm) Over
Centerline
of Cabinet
2" x 4" (5 cm x 10 cm)
or Equivalent Runners Level
with Bottom of Cutout
CUTOUT FOR SINGLE OVENS – UNDER COUNTER
NOTE: These ovens are only approved to be installed under the specific models as labeled on
the unit.
B2
Dimension Dimension Description 27" Single Oven 30" Single Oven
A Cabinet Width 25" (63.5 cm) min. 28
1
2" (72.4 cm) min.
25
1
4" (64.1 cm) max. 28
5
8" (72.7 cm) max.
B Cutout Height 27
5
8" (70.2 cm) min. 27
1
4" (69.2 cm) min.
28
1
8" (71.4 cm) max. 27
5
16" (69.4 cm) max.
C Unit Overlap Top 1" (2.5 cm) 1" (2.5 cm)
D Unit Overlap Bottom 1" (2.5 cm) 1
1
4" (3.2 cm)
E Unit Overlap Side Edges 1" (2.5 cm)
11
16" (1.75 cm)
F Junction Box Location 8
3
4" (22.2 cm) max. 9
1
2" (24.1 cm) max.
right side only right side only
Continue to Section 3.
NOTE: One cooktop may be centered over either
oven in the side-by-side installation.
Cutout – observe
all dimensions and
requirements.
2" (5.1 cm) Min.
30.5" (77.5 cm)
Center Line Center Line
Side-by-Side Installations (30" only)
Install two ovens in separate cutouts.
Cooktop
Cutout – observe
all dimensions and
requirements.
CUTOUT FOR INSTALLATION OVER A WARMING
DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven
supports above the Warming Drawer location do not obstruct the required interior depth and
height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ,
properly grounded receptacle must be installed. Refer to installation instructions packed with
the Warming Drawer for specific installation requirements.
E2
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
Continue to Section 3.
DESIGN INFORMATION
SINGLE OVEN INSTALLATIONS
The single oven may be installed in a cabinet alone or above a warming drawer. The single oven may
also be installed below a countertop or below specified cooktops. See the label on top of the oven for
approved models.
DOUBLE OVEN INSTALLATIONS
A double oven may be installed in a cabinet alone or above a warming drawer. See the label on top of
the oven for approved models.
IMPORTANT: Always refer to individual installation instructions packed with each product for specific
requirements.
CUTOUT FOR DOUBLE OVENS
(2 Thermal Ovens)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick,
shim both sides equally to establish the cutout width.
C2
Dimension Dimension Description 27" Double Oven 30" Double Oven
A Cabinet Width 27" (68.6 cm) 30" (76.2 cm)
B Cutout Width 25" (63.5 cm) min. 28
1
2" (72.4 cm) min.
25
1
4" (64.1 cm) max. 28
5
8" (72.7 cm) max.
C Cutout Height 49
11
16" (126.2 cm) min. 51
13
16" (131.6 cm) min.
50
1
8" (127.3 cm) max. 51
15
16" (131.9 cm) max.
D Overlap of Oven 1" (2.5 cm)
11
16" (1.75 cm)
Over Side Edges
of Cutout
E Clearance to Adjacent 20" (50.8 cm) min. 21" (53.3 cm) min.
Corners, Drawers, Walls,
etc., When Door Is Open
F Overlap of Oven 1" (2.5 cm) min. 1" (2.5 cm) min.
Top of Cutout
G Overlap of Oven 1" (2.5 cm) min. 1
1
4" (3.2 cm)
Bottom of Cutout
H Junction Box Location 8
3
4" (22.2 cm) max. 9
1
2" (24.1 cm) max.
right side only right side only
J Height to Bottom of 44" (111.8 cm) 47" (119.4 cm)
Junction Box
K Recommended 13
1
4" (33.7 cm) 12" (30.5 cm)
Cutout Location from
Floor
Continue to Section 3.