GE Profile PDW9200JBB Specification

Download Dimension manual of GE GE Profile PDW9200JBB Dishwasher for Free or View it Online on All-Guides.com. This version of GE GE Profile PDW9200JBB Manual compatible with such list of devices, as: GE Profile PDW9200JBB, GE Profile PDW9200JWW, GE Profile PDW9280J, GE Profile PDW9280JSS, PDW9200J

GE GE Profile PDW9200JBB Dimension manual - Page 1
1
GE GE Profile PDW9200JBB Dimension manual - Page 2
2
Specification Created 7/03
250200
TM
PDW9200/80J – GE Profile
Fully Integrated Built-In Dishwasher
Built-In Dishwasher Dimensions (in inches)
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.
R
Listed by
Underwriters
Laboratories
As an ENERGY STAR
®
partner,
GE has determined that this product
meets the ENERGY STAR
®
guidelines for energy efficiency.
This wall area
must be free of
pipes or wires
Countertop
4
6
Hot
water
line on
left
44
2
Plumbing and electrical
service must enter
inside shaded area
24" From wall
24" MIN.
90°
19" MIN. from wall
24"
MIN.
6
34-1/2±1/4"
Underside
of countertop
to floor
55
90°
Electrical
wiring on
right
Electrical
wiring is
3" from
cabinet
*
*Allow an additional 2" for the handle on PDW9800/9200 Series models.
24
25-1/4
21-1/4
4
4 (Adjustable)
34" MIN.
adj. to 35"
27-1/2
22-1/2
Dishwasher Rough-In Information
Note: Dishwasher must not be installed more than ten feet from sink for proper drainage. All plumbing and
electrical work must be in accordance with local codes.
The power cord and connections must comply with the National Electrical Code Section 422 and/or local
codes and ordinances. The cord must be no longer than six feet from the junction box to the receptacle.
Electrical Rating
Voltage AC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Hertz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Total connected load amperage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1
Calrod
®
heater watts max. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 875
For use on adequately wired 120-volt, 15-amp circuit having 2-wire service with
a separate ground wire. This appliance must be grounded for safe operation.