Panasonic CS-E12NKUAW Information

Download Information of Panasonic CS-E12NKUAW Air Conditioner, Heat Pump for Free or View it Online on All-Guides.com.

Panasonic CS-E12NKUAW Information - Page 1
1
Panasonic CS-E12NKUAW Information - Page 2
2
Multi Zone Submittal Data
Indoor: CS-E12NKUAW
Wall Mounted Heat Pump
Job Name: Approval:
Location: Date:
Engineer: Construction:
Submitted to: Unit #:
Submitted by: Drawing #:
Reference:
Power
V
/PH/Hz 230/208/1/60 Refrigeran
t
Circuit Ampacity (A) 15 Control Electronic Expansion Valve
Fuse Size, Max. (A) 15 Connection Flare
Line Size (in. O.D. Discharge) 1/4"
Indoor Unit Line Size (in. O.D. Suction) 1/2"
Fan type Cross Flow
No. Speeds 5 Dimensions (in.) Height Width Depth
RPM (High) 1300 Indoor Unit (Uncrated) 11-7/16" 34-9/32" 8-1/16"
Motor Output (W) 40
CFM (Qlo,Lo,Me,Hi,Shi) 187/246/335/425/472 Weight Indoor Outdoor
Indoor Sound Rating (Hi) (dB-A) 40 Net (lbs.) 20 82
Coil Type Aluminum Fin & Copper Tube Shipping (lbs.)
Fin Type - Pipe Type Slit Plate - Inner Rifled
Rows - F.P.I 2-19 Performance Data @ ARI Standard Conditions (230/208V)
Face Area (sq.ft) 2 Cooling
Drain Connection Size (in.) 5/8" Total Capacity (BTU/H) 10200
SEER 21
Features Dehumidification (Pints/H) 2.5
Wireless Remote Controller Standard Amps (A) 3.5
Wired Remote Controller ( CZ-RD516C ) Optional Power Inputs (W) 650
Controls Microprocessor Outdoor Sound Rating (dB-A) 47
Remote Controller LCD Wireless Type, Temp, Sensor Built In Heating
Temperature Control IC Thermostat Total Capacity (BTU/H) 14100
Air Louver (Horizontal) Manual HSPF 10.5
(Vertical) Automatic
Power Failure Automatic Restart Built-In Operating Range
Self-Diagnosis Built-In Indoor Air Intake Temp.
Air Filter Washable, Anti-Mold Cooling Maximum 90F DB/74F WB
Minimum 60F DB/52F WB
Heating Maximum 86F DB/-F WB
Minimum 60F DB/-F WB
R410A