Smeg AS28I96L Instructions For Installation And Use Manual

Download Instructions for installation and use manual of Smeg AS28I96L Cooktop for Free or View it Online on All-Guides.com. This version of Smeg AS28I96L Manual compatible with such list of devices, as: HB96CSS, PI18D/E, PLAL18DNL, PVE96, PVE98

Smeg AS28I96L Instructions for installation and use manual - Page 1
1
Smeg AS28I96L Instructions for installation and use manual - Page 2
2
Smeg AS28I96L Instructions for installation and use manual - Page 3
3
Smeg AS28I96L Instructions for installation and use manual - Page 4
4
Smeg AS28I96L Instructions for installation and use manual - Page 5
5
Smeg AS28I96L Instructions for installation and use manual - Page 6
6
Smeg AS28I96L Instructions for installation and use manual - Page 7
7
Smeg AS28I96L Instructions for installation and use manual - Page 8
8
Smeg AS28I96L Instructions for installation and use manual - Page 9
9
Smeg AS28I96L Instructions for installation and use manual - Page 10
10
Smeg AS28I96L Instructions for installation and use manual - Page 11
11
Smeg AS28I96L Instructions for installation and use manual - Page 12
12
Smeg AS28I96L Instructions for installation and use manual - Page 13
13
Smeg AS28I96L Instructions for installation and use manual - Page 14
14
Instructions for the installer
27
3.3 Regulation for natural gas
The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “3.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph “3.4 Regulation of primary air”.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Top with front controls:
Auxiliary 1.05 73 380
Semi rapid 1.65 92 420
Rapid 2.55 115 650
Ultrarapid 3.25 130 1400
Top with side controls:
Auxiliary 1.05 73 380
Semi rapid 1.65 92 450
Rapid 2.55 115 650
Ultrarapid 3.25 130 1400
3.4 Regulation of primary air
Referredtodistance“X in mm.
BURNER G20
20 mbar
G30/G31
28/37 mbar
Top with front controls:
Auxiliary 2.5 2.5
Semi rapid 1.5 2
Rapid 2.5 2
Ultrarapid 1.5 2.5
Top with side controls:
Auxiliary 3 3
Semi rapid 2 1.7 (*)
Rapid 3 2.5
Ultrarapid 1.7 3 (**)
(*) Semi rapid, rear: 2.5
(**) Ultrarapid, front: 4