Conversion Kit
10
WARNING
FIRE HAZARD
- Use a soapy solution to check that it is leak-tight.
- Never test for gas leaks with a match or other flames.
- Failure to follow this instruction can result in loss of life or
fire
6)
Follow these instructions to leak test the appliance:
Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections
indicate a leak. If a leak appears, shut off gas valve controls and adjust connections. Then check the
connections again.
NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAMES.
7)
Remove all the detergent product from the range.
Replace the parts on the burner and turn the knobs on the gas tap pins.
Light the burner and set it at minumum . Remove the knob and turn the adjustment screw next to the
gas tap pin until you obtain a suitable minimum flame. Replace the knob and check flame stability by
rapidly turning the knob from maximum to minimum. The flame should not go out.
8)
Check the flame at the maximum flame position for a blue color. It should be clean and soft in
character. No blowing or lifting of flame should occur. Occasional orange flashes are normal and reflect
different elements in the air or gas.
9)
Completely fill out the conversion label (part no. 92849A078) and attach the label in the storage
compartment beside the ID tag. Do not cover the ID tag with the conversion label.
10)
At higher altitudes, no further adjustments are necessary. Derating the burners is also unnecessary.
11)
Save the nozzles removed from the unit along with these instructions for possible future use.
NATURAL GAS:
To convert back to Natural Gas: Follow steps 1 through 11 and replace the nozzles in the order in which
they were removed.