SMEG CIR34AX Manual

Download Manual  of Smeg CIR34AX Cooktop, Hob for Free or View it Online on All-Guides.com. This version of Smeg CIR34AX Manual compatible with such list of devices, as: CIR34AX3, CIR64XS3, CIR93AX3, SA34AX3, SNZ134SS

Smeg CIR34AX Manual  - Page 1
1
Smeg CIR34AX Manual  - Page 2
2
Smeg CIR34AX Manual  - Page 3
3
Smeg CIR34AX Manual  - Page 4
4
Smeg CIR34AX Manual  - Page 5
5
Smeg CIR34AX Manual  - Page 6
6
Smeg CIR34AX Manual  - Page 7
7
Smeg CIR34AX Manual  - Page 8
8
Smeg CIR34AX Manual  - Page 9
9
Smeg CIR34AX Manual  - Page 10
10
Smeg CIR34AX Manual  - Page 11
11
Smeg CIR34AX Manual  - Page 12
12
Smeg CIR34AX Manual  - Page 13
13
Smeg CIR34AX Manual  - Page 14
14
Smeg CIR34AX Manual  - Page 15
15
Smeg CIR34AX Manual  - Page 16
16
Smeg CIR34AX Manual  - Page 17
17
Smeg CIR34AX Manual  - Page 18
18
Smeg CIR34AX Manual  - Page 19
19
Smeg CIR34AX Manual  - Page 20
20
Smeg CIR34AX Manual  - Page 21
21
Smeg CIR34AX Manual  - Page 22
22
Smeg CIR34AX Manual  - Page 23
23
Smeg CIR34AX Manual  - Page 24
24
Smeg CIR34AX Manual  - Page 25
25
Smeg CIR34AX Manual  - Page 26
26
Smeg CIR34AX Manual  - Page 27
27
Smeg CIR34AX Manual  - Page 28
28
Instructions for the Installer
11
REQUIREMENTS
1. Overhead clearances – (Measurement A)
Range hoods and exhaust fans shall be installed in
accordance with the manufacturer’s instructions. However,
in no case shall the clearance between the highest part of
the hob of the cooking appliance and a range hood be less
than 600 mm or, for an overhead exhaust fan, 750 mm.
Any other downward facing combustible surface less than
600 mm above the highest part of the hob shall be
protected for the full width and depth of the cooking surface
area in accordance with Clause 5.12.1.2. However, in no
case shall this clearance to any surface be less than 450
mm.
2. Side clearances – (Measurements B & C)
Where B, measured from the periphery of the nearest
burner to any vertical combustible surface, is less than 200
mm, the surface shall be protected in accordance with
Clause 5.12.1.2 to a height C of not less than 150 mm
above the hob for the full dimension (width or depth) of the
cooking surface area. Where the cooking appliance is fitted
with a ‘splashback’, protection of the rear wall is not
required.
3. Additional requirements for Freestanding and Elevated
Cooking
Appliaces – (Measurements D & E)
Where D, the distance from the periphery of the nearest
burner to a horizontal combustible surface is less than 200
mm, then E shall be 10 mm or more, or the horizontal
surface shall be above the trivet. See insets above.