SMEG SE2320ID Instructions Manual

Download Instructions for fitting and use of Smeg SE2320ID Cooktop, Hob for Free or View it Online on All-Guides.com.

Brand: Smeg

Category: Cooktop , Hob

Type: Instructions for fitting and use for Smeg SE2320ID

Pages: 17 (0.66 Mb)

Download Smeg SE2320ID Instructions for fitting and use

Smeg SE2320ID Instructions for fitting and use - Page 1
1
Smeg SE2320ID Instructions for fitting and use - Page 2
2
Smeg SE2320ID Instructions for fitting and use - Page 3
3
Smeg SE2320ID Instructions for fitting and use - Page 4
4
Smeg SE2320ID Instructions for fitting and use - Page 5
5
Smeg SE2320ID Instructions for fitting and use - Page 6
6
Smeg SE2320ID Instructions for fitting and use - Page 7
7
Smeg SE2320ID Instructions for fitting and use - Page 8
8
Smeg SE2320ID Instructions for fitting and use - Page 9
9
Smeg SE2320ID Instructions for fitting and use - Page 10
10
Smeg SE2320ID Instructions for fitting and use - Page 11
11
Smeg SE2320ID Instructions for fitting and use - Page 12
12
Smeg SE2320ID Instructions for fitting and use - Page 13
13
Smeg SE2320ID Instructions for fitting and use - Page 14
14
Smeg SE2320ID Instructions for fitting and use - Page 15
15
Smeg SE2320ID Instructions for fitting and use - Page 16
16
Smeg SE2320ID Instructions for fitting and use - Page 17
17
32
Instructions for assembly
GB
Electrical connection
The electrical connection must be carried out by a qualified
electrician who is authorised to carry out such work!
Statutory regulations and the connection specifications issued
by the local power supply company must be strictly observed.
When connecting the appliance it must be ensured that there
is a device which makes it possible to disconnect it from the
mains at all poles with a contact opening width of at least
3 mm. Line-protecting switches, fuses or contactors are
suitable cut-out devices. When connecting and repairing the
appliance disconnect it from the electricity supply with one of
these devices.
The earth wire must be sufficiently long so that if the strain
relief fails, the live wires of the connecting cable are subjected
to tension before the earth wire.
Any superfluous cable must be removed from the installation
area beneath the appliance.
Make sure that the local mains voltage is the same as the
voltage on the rating label.
The induction hob has been fitted with a temperature-resistant
connection cable in the factory.
The connection cable must be at least H05 RR-F.
If the excess cable of this appliance is damaged, it has to be
replaced by the manufacturer, the Customer service of the
manufacturer or by another qualified person to avoid danger.
Full protection against accidental contact must be ensured on
installation.
Attention: Incorrect connection may result in the power
electronics unit being destroyed.
Power supply
Mains voltage: 220 - 240V~, 50-60 Hz
Component rated voltage: 230 - 240V
Technical data
* Power when the power boost function is activated
* Power when the power boost function is activated
Dimensions
Hob height/ width/ depth mm 50 x 300 x 520
Cooking zones
rear Ø cm / kW
front Ø cm / kW
21/ 2.3 (3.2)*
14.5/ 1.4 (1.8)*
Hob, total kW 3.7
Dimensions
Hob height/ width/ depth mm 50 x 450 x 520
Cooking zones
Ø cm / kW 28/ 2.4 (3.7)*
Hob, total kW 3.7