SMEG Oven Instructions For The User

Download Instructions for the user of Smeg Oven Cookers, Oven for Free or View it Online on All-Guides.com.

Brand: Smeg

Category: Cookers , Oven

Type: Instructions for the user for Smeg Oven

Pages: 32 (1.02 Mb)

Download Smeg Oven Instructions for the user

Smeg Oven Instructions for the user - Page 1
1
Smeg Oven Instructions for the user - Page 2
2
Smeg Oven Instructions for the user - Page 3
3
Smeg Oven Instructions for the user - Page 4
4
Smeg Oven Instructions for the user - Page 5
5
Smeg Oven Instructions for the user - Page 6
6
Smeg Oven Instructions for the user - Page 7
7
Smeg Oven Instructions for the user - Page 8
8
Smeg Oven Instructions for the user - Page 9
9
Smeg Oven Instructions for the user - Page 10
10
Smeg Oven Instructions for the user - Page 11
11
Smeg Oven Instructions for the user - Page 12
12
Smeg Oven Instructions for the user - Page 13
13
Smeg Oven Instructions for the user - Page 14
14
Smeg Oven Instructions for the user - Page 15
15
Smeg Oven Instructions for the user - Page 16
16
Smeg Oven Instructions for the user - Page 17
17
Smeg Oven Instructions for the user - Page 18
18
Smeg Oven Instructions for the user - Page 19
19
Smeg Oven Instructions for the user - Page 20
20
Smeg Oven Instructions for the user - Page 21
21
Smeg Oven Instructions for the user - Page 22
22
Smeg Oven Instructions for the user - Page 23
23
Smeg Oven Instructions for the user - Page 24
24
Smeg Oven Instructions for the user - Page 25
25
Smeg Oven Instructions for the user - Page 26
26
Smeg Oven Instructions for the user - Page 27
27
Smeg Oven Instructions for the user - Page 28
28
Smeg Oven Instructions for the user - Page 29
29
Smeg Oven Instructions for the user - Page 30
30
Smeg Oven Instructions for the user - Page 31
31
Smeg Oven Instructions for the user - Page 32
32
Installation
25
EN
5 Installation
5.1 Gas connection
General information
Connection to the gas supply network can
be made using a continuous wall flexible
steel hose in compliance with the guidelines
established by the standards in force. The
appliance is preset for natural gas G20
(2H) at a pressure of 20 mbar. For
supplying it with other types of gas, see
chapter “5.2 Adaptation to different types
of gas”. The gas inlet connection is
threaded ½” external gas (ISO 228-1).
Connection with a rubber hose
Verify that all following conditions are met:
• the hose is fixed to the hose connection
with safety clamps;
• no part of the hose is in contact with hot
walls (max. 50 °C);
• the hose is not under traction or tension
and has no kinks or twists;
• the hose is not in contact with sharp
objects or sharp corners;
• if the hose is not perfectly airtight and
leaks gas, do not try to repair it; replace
it with a new hose.
• verify that the hose is not past its expiry
date (serigraphed on the hose itself).
Make the connection to the gas mains
using a rubber hose whose specifications
comply with current standards (verify that
the reference standard is stamped on the
hose).
Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and 15
Nm.
• If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.
• Installation with flexible hose must be
carried out so that the length of the
piping does not exceed 2 metres when
fully extended as regards flexible steel
hoses and 1.5 metres in case of rubber
hoses.
• The hoses should not come into contact
with moving parts and should not be
crushed in any way.