Smeg CSA19ID-6 Owner's Manual

Download Owner's manual of Smeg CSA19 Microwave Oven for Free or View it Online on All-Guides.com. This version of Smeg CSA19 Manual compatible with such list of devices, as: CSA19, CSA196A, CSA196XLP, CSA19A, CSA19B

Smeg CSA19 Owner's manual - Page 1
1
Smeg CSA19 Owner's manual - Page 2
2
Smeg CSA19 Owner's manual - Page 3
3
Smeg CSA19 Owner's manual - Page 4
4
Smeg CSA19 Owner's manual - Page 5
5
Smeg CSA19 Owner's manual - Page 6
6
Smeg CSA19 Owner's manual - Page 7
7
Smeg CSA19 Owner's manual - Page 8
8
Smeg CSA19 Owner's manual - Page 9
9
Smeg CSA19 Owner's manual - Page 10
10
Smeg CSA19 Owner's manual - Page 11
11
Smeg CSA19 Owner's manual - Page 12
12
Smeg CSA19 Owner's manual - Page 13
13
Smeg CSA19 Owner's manual - Page 14
14
Smeg CSA19 Owner's manual - Page 15
15
Smeg CSA19 Owner's manual - Page 16
16
Smeg CSA19 Owner's manual - Page 17
17
Smeg CSA19 Owner's manual - Page 18
18
Smeg CSA19 Owner's manual - Page 19
19
Smeg CSA19 Owner's manual - Page 20
20
Smeg CSA19 Owner's manual - Page 21
21
Smeg CSA19 Owner's manual - Page 22
22
Smeg CSA19 Owner's manual - Page 23
23
Smeg CSA19 Owner's manual - Page 24
24
Smeg CSA19 Owner's manual - Page 25
25
Smeg CSA19 Owner's manual - Page 26
26
Smeg CSA19 Owner's manual - Page 27
27
Smeg CSA19 Owner's manual - Page 28
28
Smeg CSA19 Owner's manual - Page 29
29
Smeg CSA19 Owner's manual - Page 30
30
Smeg CSA19 Owner's manual - Page 31
31
Smeg CSA19 Owner's manual - Page 32
32
Instructions for the installer
3.2 Adjustment for LPG
Loosen screw A and push air regulator B to
the bottom. With a 7 mm wrench, remove
nozzle C and replace it with the proper one
(follow the instructions on the reference
tables for the type of gas to be used). The
torque wrench setting of the nozzle must not
exceed 3 Nm. Adjust the air by sliding
regulator B until reaching distance “X
shown in the table in paragraph “3.4
Regulation of primary air”. Lock regulator B
by tightening screw A.
Model CSA19
Models CSA196 / CSA20
LPG – 2.75 kPa
LPG – 2.75 kPa
Burner
Nominal gas
consumption
(MJ/h)
Turn-down gas
consumption
(MJ/h)
Injector
(mm)
Nominal gas
consumption
(MJ/h)
Turn-down gas
consumption
(MJ/h)
Injector
(mm)
Auxiliary 4.80 1.5 0.60 5.30 1.5 0.62
Semi rapid 5.80 1.5 0.67 6.60 1.5 0.70
Rapid 9.30 3.2 0.85 9.00 3.2 0.82
Wok 13.00 5.4 1.00 15.00 5.4 1.05
Fish burner (*) 9.20 3.2 0.85 6.60 2.9 0.70
(*) Models CSA19 / CSA196
3.3 Adjustment for natural gas
The hob has been tested for natural gas at a pressure of 1.0kPa. To
allow the unit to work with this type of gas, perform the same operations
described in paragraph “3.2 Adjustment for LPG”, but choose the nozzles
and adjust the primary air for natural gas, as shown in the following table
and in paragraph “3.4 Regulation of primary air”.
Model CSA19
Models CSA196 / CSA20
NG – 1.00 kPa
NG 1.00 kPa
Burner
Nominal gas
consumption
(MJ/h)
Turn-down gas
consumption
(MJ/h)
Injector
(mm)
Nominal gas
consumption
(MJ/h)
Turn-down gas
consumption
(MJ/h)
Injector
(mm)
Auxiliary 5.30 1.4 1.04 5.30 1.4 1.00
Semi rapid 6.60 1.4 1.15 6.60 1.4 1.15
Rapid 9.00 2.4 1.35 9.00 2.4 1.35
Wok 12.50 4.3 1.65 15.00 4.3 1.75
Fish burner (*) 10.20 3.2 1.45 6.60 2.9 1.15
(*) Models CSA19 / CSA196
1
2