SMEG CA12SHRPX Instructions Manual

Download Instructions manual of Smeg CA12SHRPX Other for Free or View it Online on All-Guides.com. This version of Smeg CA12SHRPX Manual compatible with such list of devices, as: KD120X-2, KSE86PO, KSE89P9, KSED62X, KSED75X

Brand: Smeg

Category: Other

Type: Instructions manual

Model: Smeg CA12SHRPX , Smeg CA12SHRX , Smeg CA12SRPX , Smeg CA12SRX , Smeg CA60EPX , Smeg CA60EPX8 , Smeg CA60EX , Smeg CA60EX8 , Smeg CA6EX , Smeg CA6SHRX , Smeg CA6SRX , Smeg CA70EPX , Smeg CA70EPX8 , Smeg CA70EX , Smeg CA70EX8 , Smeg CA90EPX , Smeg CA90EPX8 , Smeg CA90EX , Smeg CA90EX8 , Smeg CA9EX , Smeg CA9SHRPX , Smeg CA9SHRX , Smeg CA9SRPX , Smeg CA9SRX , Smeg CA9X , Smeg CAV9X , Smeg CAV9XB , Smeg CPE400X , Smeg CSED65X , Smeg CSED75X , Smeg CSED95X , Smeg CSEM90X , Smeg CSEM90X8 , Smeg DH1016S , Smeg DH1018S , Smeg DH1021S , Smeg DH1021S12 , Smeg DH1021S1A , Smeg DH1022S , Smeg DH1026S , Smeg DH1030S , Smeg ES3000T , Smeg K135X , Smeg K2-AUS , Smeg K200X , Smeg K200X-1 , Smeg K2A , Smeg K300X , Smeg K3020 , Smeg K3A , Smeg K42A , Smeg K42B , Smeg K42G , Smeg K42X , Smeg KA1VA , Smeg KA1VA2 , Smeg KA1VG , Smeg KA1VP , Smeg KA1VP9 , Smeg KA9X , Smeg KA9X-1 , Smeg KAP1200HX , Smeg KAP1200X , Smeg KAP1200XT , Smeg KAP600HX , Smeg KAP600X , Smeg KAP700X , Smeg KAP800X , Smeg KAP900HX , Smeg KAP900X , Smeg KAP900XT , Smeg KD100B , Smeg KD100N , Smeg KD100N-2 , Smeg KD100RW , Smeg KD100X , Smeg KD100X-1 , Smeg KD100X-2 , Smeg KD120X , Smeg KD120X-1 , Smeg KD120X-2 , Smeg KD120XU , Smeg KD150X-1 , Smeg KD150X-2 , Smeg KD70X , Smeg KD70X-1 , Smeg KD90B , Smeg KD90N , Smeg KD90N-2 , Smeg KD90NU , Smeg KD90RW , Smeg KD90RW-2 , Smeg KD90RWU , Smeg KD90X , Smeg KD90X-1 , Smeg KD90X-2 , Smeg KD90XU , Smeg KMD1030XL , Smeg KMD730XL , Smeg KMD930XL , Smeg KRA1200X , Smeg KRA900X , Smeg KRA960X , Smeg KS1250X1 , Smeg KS1260XL1 , Smeg KS12X-AUS , Smeg KS9500X1 , Smeg KS9600XL1 , Smeg KS9P , Smeg KS9X-AUS , Smeg KS9XSEK , Smeg KSA6EX8 , Smeg KSA9EX8 , Smeg KSA9EXPK , Smeg KSC9222X , Smeg KSE110BL , Smeg KSE110WH , Smeg KSE110X , Smeg KSE12000X , Smeg KSE1250X , Smeg KSE1260XL , Smeg KSE605X , Smeg KSE6500X , Smeg KSE6600XL , Smeg KSE7700A , Smeg KSE7700X , Smeg KSE86AO , Smeg KSE86AO9 , Smeg KSE86PO , Smeg KSE86PO9 , Smeg KSE89A2 , Smeg KSE89AO , Smeg KSE89AO9 , Smeg KSE89D2 , Smeg KSE89D9 , Smeg KSE89P , Smeg KSE89P9 , Smeg KSE89PO , Smeg KSE89PO9 , Smeg KSE89RA , Smeg KSE89RA2 , Smeg KSE9000X , Smeg KSE905X , Smeg KSE9100X , Smeg KSE9500X , Smeg KSE9510X , Smeg KSE9600XL , Smeg KSE9700A , Smeg KSE9700X , Smeg KSE9800XL , Smeg KSED102X , Smeg KSED62X , Smeg KSED65N , Smeg KSED65X-1 , Smeg KSED72X , Smeg KSED75X , Smeg KSED75X-1 , Smeg KSED92EB , Smeg KSED92NE , Smeg KSED92X , Smeg KSED95N , Smeg KSED95P , Smeg KSED95P9 , Smeg KSED95X-1 , Smeg KSED95XT , Smeg KSEM90X-1 , Smeg KSEM90X8 , Smeg KSEM90XT , Smeg KSEP600X , Smeg KSEP900X , Smeg KSEP920X , Smeg KV90 , Smeg KV90-1 , Smeg KV90XL , Smeg KVB91 , Smeg LD102D

Pages: 8 (0.49 Mb)

Download Smeg CA12SHRPX Instructions manual

Smeg CA12SHRPX Instructions manual - Page 1
1
Smeg CA12SHRPX Instructions manual - Page 2
2
Smeg CA12SHRPX Instructions manual - Page 3
3
Smeg CA12SHRPX Instructions manual - Page 4
4
Smeg CA12SHRPX Instructions manual - Page 5
5
Smeg CA12SHRPX Instructions manual - Page 6
6
Smeg CA12SHRPX Instructions manual - Page 7
7
Smeg CA12SHRPX Instructions manual - Page 8
8
Recirculation mode:
Leave the motor intake free. Install the active carbon
filters as shown in page 6.
Warning: if the hood is not supplied with an active
carbon filter, it is necessary to buy it separately and
assemble it before using the hood.
i) Chimney assembly:
Adjust the two telescopic chimneys to the required
length (fig. 6).
Secure the chimneys by tightening the two H screws .
Place the chimney group on the top side of the hood
carefully. Put the chimney bracket
K
on the
B
chimney (fig. 6). Mark the holes on the wall for fixing
the chimney bracket to the wall.
Remove the chimney set, drill and fix the support
bracket to the wall by means of wall anchors. Put the
chimney group back in place and fix it to the hood with
the Z screws and to the chimney bracket with the L
screws as shown in figure 6.
ELECTRICAL CONNECTION
It is recommended that all electrical connection
operations are performed by a qualified technician.
The appliance is supplied WITHOUT A PLUG. It is
therefore necessary to fix a plug to the cable or hard
wire direct to a spur. The plug and fuse must be in
accordance with the rating plate inside the hood. Then
connect it to a nearby, easily reachable socket in
accordance with the rules in force.
In the case of a direct connection to the mains supply,
it is necessary to put a switched spur between the
appliance and the mains supply. The switch must be
suitable for the load, compliant with the rules in force
and must have a minimum contact opening of not less
than 3mm.
EN 03
OPERATING INSTRUCTIONS:
ü CONTROL PANEL:
In order to achieve the best performance, it is recommended to start the hood a few
minutes before starting cooking and keep it on for at least 15 minutes after finishing
cooking or after all fumes and odours have disappeared.
To start the hood, identify your type of control panel and follow the instructions:
Ø SLIDER:
- Key (A) to turn on/off the hood’s light.
- Four-position Cursor (B):
0: Off
1/2/3: On/Speed adjustment
Ø ELECTROMECHANICAL PUSHBUTTONS:
Light ON/OFF Button
0 Motor OFF button
1-2-3 On/speed adjustment button
Ø WITH KNOBS:
- Two-position Knob (A) to turn on/off
the light (0-1)
- Four-position Knob (B):
0 Motor OFF
1-2-3 Speed adjustment
EN 04
A
B
(A) (B)
(A) (B)
Fig.4
Fig.5
Fig.6
K
B
Z
Z