Smeg CMVANILLA Instructions Manual

Download Instruction manual of Smeg CMVANILLA Ventilation Hood for Free or View it Online on All-Guides.com.

Brand: Smeg

Category: Ventilation Hood

Type: Instruction manual

Model: Smeg CMVANILLA , Smeg CMVERTIGO , Smeg CMZOOM

Pages: 24 (1.28 Mb)

Download Smeg CMVANILLA Instruction manual

Smeg CMVANILLA Instruction manual - Page 1
1
Smeg CMVANILLA Instruction manual - Page 2
2
Smeg CMVANILLA Instruction manual - Page 3
3
Smeg CMVANILLA Instruction manual - Page 4
4
Smeg CMVANILLA Instruction manual - Page 5
5
Smeg CMVANILLA Instruction manual - Page 6
6
Smeg CMVANILLA Instruction manual - Page 7
7
Smeg CMVANILLA Instruction manual - Page 8
8
Smeg CMVANILLA Instruction manual - Page 9
9
Smeg CMVANILLA Instruction manual - Page 10
10
Smeg CMVANILLA Instruction manual - Page 11
11
Smeg CMVANILLA Instruction manual - Page 12
12
Smeg CMVANILLA Instruction manual - Page 13
13
Smeg CMVANILLA Instruction manual - Page 14
14
Smeg CMVANILLA Instruction manual - Page 15
15
Smeg CMVANILLA Instruction manual - Page 16
16
Smeg CMVANILLA Instruction manual - Page 17
17
Smeg CMVANILLA Instruction manual - Page 18
18
Smeg CMVANILLA Instruction manual - Page 19
19
Smeg CMVANILLA Instruction manual - Page 20
20
Smeg CMVANILLA Instruction manual - Page 21
21
Smeg CMVANILLA Instruction manual - Page 22
22
Smeg CMVANILLA Instruction manual - Page 23
23
Smeg CMVANILLA Instruction manual - Page 24
24
EN
1
19
USE
Control panel
L T1
Button Function Display
L Turns the lights On/Off.
-
T1 Hood Down
Press for 2 seconds to raise the Hood.
Press briefly to turn the Motor On/Off.
On/Off
Hood Up
Press once: The Hood lowers.
Press a second time: The Hood Stops.
When the movement has been completed
the motor turns on at Speed two.
Off/Off
Warning: The Hood controls only control the Hood functions. The Lighting unit has a com-
pletely separate power supply and a separate switch.
The electronic control system recognises and signals two types of fault.
Led T1
Slow flashing
Current absorption threshold exceeded:
If an overload condition occurs, the fault is signalled by LED T1 on the
keyboard flashing once every 2 seconds. Check that nothing is blocking
normal hood movements.
The signal remains active until a new hood open/close command is given.
Rapid flashing
Hood opening safety microswitch tripped:
If the safety microswitch trips, the fault is signalled by LED T1 on the
keyboard flashing quickly (once every 250 ms). This means that the hood
has passed the microswitch…….. Call Technical Assistance!
You can continue to use the hood’s light and motor functions while this
fault is active. Whenever the motor is on, LED T1 will continue to flash,
indicating that the fault is still present.