INSTALLATION
3 - INSTALLATION
The following scheme has to be observed:
3.1 - Installation of the built-in group
3.2 - Set the hood for recirculation or evacuation
3.2 - Connect the hood to the mains supply and ensure that it works properly
3.1 - Installation of the fitted group
1 - Make a rectangular opening in the base of the overhead cupboard or hood, leaving a minimum
of 13 mm from the outer edges according to the dimensions indicated in the table.
2 - Drill a hole into the upper side of the cabinet in accordance with the dimensions of the duct
used for both the evacuation and recirculation mode.
3 - Dismantle the ducting support (version with grill or version with filters), pulling the two pom-
mels A (fig. 1) simultaneously:
a) Fixing frame with screws:
Fix the fitted group to the hood or cupboard, using the self-threading screws (No. 8) pro-
vided with the accessories (fig. 2).
b) Rapid fixing with side supports:
The device B is set up to deal with a panel thickness of from 15 mm to 30 mm. Insert the
group into the opening until the two devices B connect. Lock the adjustment screw C until
the fitted group adheres tightly to the surface (fig. 2).
4 - Close the ducting support by pushing and connecting the two pommels A (fig. 3).
3.2 - Ducting or recirculation fitting
1 - Ducting fitting:
a - The hood can be ducted to the outside using either a rigid or a flexible Ø 100 or 120 mm
duct to be fixed with suitable clamps, not provided (fig. 2).
b - If the hood is provided with the charcoal filters fitted, the filters should be removed (see
par.6.2).
2 - Recirculation fitting:
a - When used in the recirculation mode, the charcoal filters must be fitted into the cooker
hood (see par. 6.2).
b - The air is recirculated into the kitchen through the opening located on the upper side of the
cabinet or of the hood (fig. 3).
3.3 - Electrical connection and working test
1 - The safety measures 4.2, 4.3 and 4.4.
2 - Once the electrical connection has been completed, check that the worktop illumination, motor
and speeds work properly.
520 mm
700 mm
Side A
497 mm
677 mm
Side B
259 mm
259 mm
Cooker Hood
Dimensions