9
PUT ON BOWL SEAL AND SHAFT SEAL
Moisten bowl seal (T) with water
and put back on
Check for wear of bell shaped rubber
shaft seal (see below ) replace if needed
Lubricate inside of bell shaped shaft
seal (X) with food grade lubricant. Put
back seal making sure flared side faces
the cylinder
10
PUT ON GEAR RING/AUGER ASSEMBLY
Put gear ring/auger assembly (U)
back in position
Secure parts in place by screwing on
the bolt (S) counterclockwise
11
PUT ON BOWL
Lightly moisten rear inner part of bowl
with food grade lubricant
Position bowl into place making sure
it has a tight hold on the bowl seal
Be sure bowl corners fit on outside edge of the top tray piece. The
lid cover will not fit properly if the bowl is not correctly positioned.
12
SECURE BOWL WITH KNOBS
Keep bowl lifted until the hole in lower bowl
edge is aligned with hole in front panel then
tightly screw on the knobs (P) without exerting
excessive pressure to avoid cracking the bowl
13
REASSEMBLE DISPENSING VALVE
Lubricate o-rings with food grade
lubricant and place o-rings on valve
Place spring over valve stem
While pushing up on valve, insert
metal bar on handle under hook on valve
Slide valve back into position until it
completely snaps into place
Reassemble the handle (B) with the rele-
vant pin (G ) (See #5).
14
REASSEMBLE MIXING ROD
Reassemble mixing rod (O) so that
its gears are aligned with the lower
gear ring
Insert front pin into position at
front of bowl
15
INSTALL DRIP TRAY
Reinstall drip tray, (AA) making sure that
the condensation drainage tube (AB) is
reinserted into its correct fixed position
allowing it to drain into the tray
Plug unit into appropriate power supply
16
SANITIZING UNIT
Fill bowl with a mix of water and sanitizing solution
Turn auger on for 10 minutes to sanitize all parts
Turn off auger
Drain bowl through dispensing valve
Unscrew two knobs and lower bowl to drain out remaining solution
Clean tray underneath bowl and lubricate rear bowl seal
Reattach bowl
Screw knobs back on
Disconnect lamp cover from power. With clean cloth wash
underside of lamp cover with warm water and mild detergent.
Allow to air dry and wipe with cloth that has been dipped in
sanitizing mixture
CAUTION: MAKE SURE LAMP COVER HAS BEEN DISCONNECTED FROM
POWER.
1
TURN OFF ALL SWITCHES, EMPTY BOWL
& UNPLUG UNIT
Turn off refrigeration / and
/ freezing switches and empty the
bowls of their remaining product
• Turn off auger switches and power switch
• Unplug the unit
2
REMOVE MIXING ROD
Pull out the mixing rod (O) by
pushing it slightly backwards
to remove it from its position
3
REMOVE KNOBS SECURING BOWL -
DRAIN EXCESS PRODUCT
Unscrew and remove the two knobs (P)
Then lower the bowl to drain out
any remaining product through the
dispensing valve (l)
4
REMOVE BOWLS
Remove bowl by pulling it outwards,
lightly tapping the back of bowl so
it comes out of position or by applying
slight downward pressure to the top front
edge of the bowl.
5
REMOVE DISPENSING VALVE
Remove the pin (G) and slide the
handle out from it’s seat.
Simultaneously apply pressure to the
securing tabs, lift the dispensing valve
out of its position.
• Disassemble remaining valve assembly
parts
6
REMOVE O-RINGS FROM DISPENSING VALVE
Pinch o-ring between thumb
and index finger
Squeeze and push o-ring out
of the groove
Roll o-ring out of the groove with
your other thumb
7
REMOVE MIXING UNIT PARTS & DRIP TRAY
• Unscrew bolt (S) clockwise
• Pull off auger and gear ring assembly (U)
Remove bowl seal (T) and bell shaped shaft
seal (X)
Remove drip tray by lifting up the front edge,
while lowering the rear edge and pulling
it towards you
8
CLEAN ALL PARTS
Thoroughly clean all parts removed
above as well as the base (Y) and
evaporator (Z).
• Wash with warm water using
a mild dish detergent and rinse
thoroughly with clean water.
Allow to air dry.
CAUTION: DO NOT USE ABRASIVE CLEANERS OR SCRUB PADS.
ABRASIVES WILL SCRATCH PLASTIC PARTS AND OTHER FINISHES.
TO DISASSEMBLE TO RE-ASSEMBLE
G & MG & ID Series Granita Machines
Operators
Manual
B
K
O
P
O
S X
U
T
S
X U
T
O
AA
AB
I
S X
U
T
DAILY CARE & CLEANING INSTRUCTIONS:
For the machine to function properly, it is important that the cleaning procedures be carried out daily.