Haier AE092FSAHA Specifications

Download Wiring manual of Haier AE092FSAHA Air Conditioner for Free or View it Online on All-Guides.com. This version of Haier AE092FSAHA Manual compatible with such list of devices, as: AE092FSAHA, AE112FSAHA, AE182FSAHA, AE242FSAHA

Haier AE092FSAHA Wiring manual - Page 1
1
Haier AE092FSAHA Wiring manual - Page 2
2
Specifications
0010573683 D
2. Error display
1. Applicable ambient temperature range:
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 21 -15
6 15 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
Indoor unit malfunction display code
Please keep this manual carefully and safely.
Outdoor unit malfunction display code
When the wire remote controller display E1,Can check the outdoor unit control board LED1 or outdoor
unit malfunction display code to sure outdoor unit malfunction.
Indoor unit malfunction Display code
Float switch or water motor abnormal E0
Outdoor unit abnormal E1
Liquid temperature sensor is abnormal
E3
Gas temperature sensor is abnormal
E4
Indoor unit adress abnormal
(Firstly you saw E5 in controller LCD,
and then the failure code is changed
from E5 to E9)
E5
The communication with electronic
expansion box is abnormal
E7
The communication between the
wire remote controller and indoor
unit control board is abnormal
E8
The communication between indoor
and outdoor unit is abnormal
E9
Water temp. sensor is abnormal EB
Display codeIndoor unit malfunction
Timer indicator
Flashing times
Indoor unit malfunction
Flashing once
The liquid tube temperature sensor is abnormal
Flashing twice
The gas tube temperature sensor is abnormal
Flashing 3 times The environment temperature sensor is abnormal
Flashing 4 times The communication with outdoor unit is abnormal
Flashing 5 times
The ommunication with the electronic expansion valve control board is abnormal
Flashing 10 times
Indoor unit PG fan motor is abnormal
Flashing 11 times
Indoor unit water overflow or float switch is abnormal
Flashing 12 times Indoor unit EEPROM data is abnormal
Remote controller Timer and Operation indicator malfunction code
When the unit running, Timer indicator flash stand for indoor unit malfunction
When the operation indicator flashing stand for outdoor unit malfunction,Operation indicator flashing
times can't determinant outdoor unit malfunction ,You must check the outdoor unit control board LED1
flashing times or outdoor unit malfunction display code to sure outdoor unit malfunction.
Others malfunction manual plese read the outdoor unit manual.
E6
Indoor unit EEPROM data is abnormal
0010573683
Electric wiring
NOTE: 1. Ceiling concealed type must be connected MP2A or MP3A
(TES indoor units not included).
2. Connect method of MP3A is follwing
Matrix of the dial switch and indoor unit number
Field setting
Field setting the unit number
In order to realize central control of the MRV air conditioning system, its necessary to set
the indoor unit number (control address).
Indoor unit number setting
Indoor unit number setting switch and confirmation of the settings.
There is a 4-position dial switch for setting the indoor unit number and fan speed level on
the computer board of the indoor unit.
Setting way is as follows:
Before connecting the power supply, please set the indoor unit number manually according
to the following table
1 0 0
Pos.1 Pos.2 Pos.3 Pos.4
Setting for No. 2 indoor unit
D
"ON" means that the indoor unit fan
speed can be choosed to middle and low
level. "OFF" means that the indoor unit
fan speed can be choosed to high, middle
and low level.After producing in plant ,
the position is "OFF".
0 0 0 1
1 0 0 2
0 1 0 3
1 1 0 4
0 0 1 5
1 0 1 6
Position 1 Position 2 Position 3 Representing unit number
0 1 1
7
1 1 1
8
Example:
: 0
: 1
ON
OFF
SW01
Example:
ON
OFF
SW02
Example:
ON
OFF
SW03
1
1.The power supply and communication wiring of indoor electronic expansion valve must be connected with their
corresponding indoor unit.And their phase sequence must correspond with the remarks strictly respectively, or will
cause control board of indoor unit and electronic expansion valve box abnormal or damaged.
2.Because the power supply of MP3A control board is joined from "indoor 1","indoor 1" must be always electrified in
running mode, or will cause performance abnormal.
3.
MP3A wiring and indoor wiring: H05RNF 4 x (1.0-1.5)mm
2
,H05RNF 3x(1.0-1.5)mm
2
.
NOTE
BR
BRWB B W
Y/G
B W BR
W
B R
W
B R
Outdoor control circuit
Short circuit protector
"Indoor 2"
control board
Outdoor Indoor
outdoor power supply
1PH.220-230V~.50Hz
"Indoor 3"
control board
"Indoor 1"
control board
Electronic expansion valve
driver board(MP3A)
L N
C1
C2
Indoor power supply
1PH.220-230V~.50Hz
1 2 3
1 2 3
C1 C2C1 C2
1 2 3
C1 C2
L1
N1
C1
L2 N2 C2
L3
N3 C3
Y/G
Y/G
W
B R
Y/G
Y/G
Indoor power supply
1PH.220-230V~.50Hz
Indoor power supply
1PH.220-230V~.50Hz